Critical review of non-invasive respiratory monitoring in medical care
Top Cited Papers
- 1 July 2003
- journal article
- review article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 41 (4), 377-383
- https://doi.org/10.1007/bf02348078
Abstract
Respiratory failure can be difficult to predict. It can develop into a life-threatening condition in just a few minutes, or it can build up more slowly. Thus continuous monitoring of respiratory activity should be mandatory in clinical, high-risk situations, and appropriate monitoring equipment could be life-saving. The review considers non-invasive methods and devices claimed to provide information about respiratory rate or depth, or gas exchange. Methods are categorised into those responding to movement, volume and tissue composition detection; air flow; and blood gas concentration. The merits and limitations of the methods and devices are analysed, considering information content and their ability to minimise the rate of false alarms and false non-alarms. It is concluded that the field of non-invasive respiratory monitoring is still in an exploratory phase, with numerous reports on specific device solutions but less work on evaluation and adaptation to clinical requirements. Convincing evidence of the clinical usefulness of respiratory monitors is still lacking. Devices responding only to respiratory rate, and lacking information about actual gas exchange, will have limited clinical value. Furthermore, enhancement in specificity and sensitivity to avoid false alarms and non-alarms will be necessary to meet clinical requirements. Miniature CO2 sensors are identified as one route towards substantial improvement.Keywords
This publication has 63 references indexed in Scilit:
- Prone versus supine sleep position: A review of the physiological studies in SIDS researchJournal of Paediatrics and Child Health, 2002
- Comparison of impedance and inductance ventilation sensors on adults during breathing, motion, and simulated airway obstructionIEEE Transactions on Biomedical Engineering, 1997
- End-tidal PCO2 monitoring via nasal cannulae in pediatric patients: Accuracy and sources of errorJournal of Clinical Monitoring and Computing, 1996
- Presentation and evaluation of a new optical sensor for respiratory rate monitoringJournal of Clinical Monitoring and Computing, 1994
- Experimental evaluation of two new sensors for respiratory rate monitoringPhysiological Measurement, 1993
- A new respiratory rate monitor: development and initial clinical experienceJournal of Clinical Monitoring and Computing, 1993
- Circadian variation in unexpected postoperative deathBritish Journal of Surgery, 1992
- A Single-blind Study of Combined Pulse Oximetry and Capnography in ChildrenAnesthesiology, 1991
- Respiratory monitoring with a new impedance plethysmographAnaesthesia, 1986
- CO2production and breathing pattern during invasive and non-invasive respiratory monitoringActa Anaesthesiologica Scandinavica, 1986