Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees: Influence of insertion torque, tunnel-bone block gap, and interference
- 1 March 1996
- journal article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 3 (4), 238-244
- https://doi.org/10.1007/bf01466626
Abstract
A failure analysis of interference screw fixation was performed to test the hypothesis that bovine and/or elderly human cadavers are appropriate models for bonepatellar tendon-bone anterior cruciate ligament (ACL) reconstruction fixation studies. Failure mode is an important criterion for validating experimental models. The bovine, young human, and elderly human failure loads were 799±261 N, 655±186 N, and 382±118 N, respectively, and the failure modes were 75%, 69%, and 30% tissue failures, respectively. The similarities between the bovine and young human models in failure loads and failure modes indicate that bovine models are appropriate for ACL reconstruction fixation studies. The statistically significant differences between the young human and elderly human models in failure loads and failure modes indicate that elderly human cadavers are not an appropriate model for ACL reconstruction fixation studies. The differences in failure modes are consistent with previous studies using elderly human cadavers in which the predominant failure mode was bone block pullout. The tissue failures observed in the bovine and young human models contradict previous studies suggesting fixation strength is the weakest link in bone-patellar tendon-bone ACL reconstruction. Results of linear regression modeling showed statistically significant correlations between insertion torque and failure load (R 2=0.44,PR 2=0.18,P=0.003) when data from all models was combined. Results for the bovine model multiple regression showed a statistically significant regression of insertion torque (linear) and interference (quadritic) versus failure load (R 2=0.56,P=0.02). Regression slopes for screw diameter (P=0.52) and gap size (P=1.00) were not statistically significant. These results indicate that insertion torque and interference are independent predictors of failure load and should be included in future interference screw studies in addition to bone block dimensions, tunnel size, gap size, and screw diameter. Clinicians may consider using insertion torque and interference as indicators of postoperative graft fixation regarding rehabilitation decisions.Keywords
This publication has 15 references indexed in Scilit:
- Primary Stability of Interference Screw FixationThe American Journal of Sports Medicine, 1994
- The biomechanics of interference screw fixation of patellar tendon anterior cruciate ligament graftsThe American Journal of Sports Medicine, 1993
- Effect of varying angles on the pullout strength of interference screw fixationArthroscopy: The Journal of Arthroscopic & Related Surgery, 1993
- The effect of early versus late return to vigorous activities on the outcome of anterior cruciate ligament reconstructionThe American Journal of Sports Medicine, 1993
- The biomechanical effects of geometric configuration of bone-tendon-bone autografts in anterior cruciate ligament reconstructionArthroscopy: The Journal of Arthroscopic & Related Surgery, 1992
- Accelerated rehabilitation after anterior cruciate ligament reconstructionThe American Journal of Sports Medicine, 1990
- Load Tolerance, Security, and Failure Modes of Fixation Devices for Synthetic Knee LigamentsPublished by Wolters Kluwer Health ,1990
- A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstructionThe American Journal of Sports Medicine, 1987
- The effect of continuous passive motion on anterior cruciate ligament reconstruction stabilityThe American Journal of Sports Medicine, 1984
- Vascularized Patellar Tendon Graft with Rigid Internal Fixation for Anterior Cruciate Ligament InsufficiencyClinical Orthopaedics and Related Research, 1983