Applications of Sol−Gel-Derived Membranes to Neutral Carrier-Type Ion-Sensitive Field-Effect Transistors
- 1 July 1997
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 69 (13), 2379-2383
- https://doi.org/10.1021/ac9611069
Abstract
Sol-gel-derived membranes encapsulating neutral carriers, such as valinomycin and a bis(crown ether) derivative, were fabricated as novel ion-sensing membranes for neutral carrier-type ion-sensitive field-effect transistors (ISFETs). The neutral carrier-type sol-gel-derived membranes obtained with an initial diethoxydimethylsilane/tetraethoxysilane ratio of 3 gave excellent results for membrane processibility and sensitivity, response time, and selectivity in the resulting ion sensors. The sol-gel-derived ion-sensing membranes containing neutral carriers are superior in the thrombogenic property to their corresponding plasticized poly(vinyl chloride) membranes. The potassium and sodium ISFETs thus obtained were successfully applied to the ion assay in blood sera.Keywords
This publication has 10 references indexed in Scilit:
- Effects of α-Substituents on Ion Selectivity of Bis(12-crown-4-methyl) Malonates as Neutral Carriers for Sodium Ion-Selective ElectrodesAnalytical Sciences, 1996
- Neutral-Carrier-Type Ion-Sensing Membranes Based on Sol-Gel-Derived GlassChemistry Letters, 1995
- Thrombogenic Properties of Untreated and Poly(ethylene oxide)-Modified Polymeric Matrixes Useful for Preparing Intraarterial Ion-Selective ElectrodesAnalytical Chemistry, 1995
- Practical Applicability of Silicone Rubber Membrane Sodium-Selective Electrode Based on Oligosiloxane-Modified Calix[4]arene Neutral CarrierAnalytical Chemistry, 1995
- Silicone-rubber membrane sodium-ion sensors based on calix[4]arene neutral carriersPure and Applied Chemistry, 1995
- Comparison between silicone-rubber membranes and plasticized poly(vinyl chloride) membranes containing calix[4]arene ionophores for sodium ion-sensitive field-effect transistors in applicability to sodium assay in human body fluidsSensors and Actuators B: Chemical, 1994
- All solid-state poly(vinyl chloride) membrane ion-selective electrodes with poly(3-octylthiophene) solid internal contactThe Analyst, 1994
- Unsymmetrical calix[4]arene ionophore/silicone rubber composite membranes for high-performance sodium ion-sensitive field-effect transistorsAnalytical Chemistry, 1992
- Chemical processing of advanced materialsMaterials & Design (1980-2015), 1992
- Determination of the equivalence point in potentiometric titrations. Part IIThe Analyst, 1952