Evaluation of 200 consecutive IOGEL 1103 capsular-bag lenses implanted through a small incision
- 1 May 1992
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 18 (3), 252-264
- https://doi.org/10.1016/s0886-3350(13)80902-9
Abstract
We evaluated 200 consecutive IOGEL 1103 capsular bag intraocular lenses. We performed a 5 to 6 mm capsulorhexis and inserted the intraocular lens (IOL) through a 3.5 to 4.0 mm scleral tunnel with a Faulkner folder. Twenty-two cases were combined with trabeculectomy and ten with keratoplasty using a temporary keratoprosthesis. Mean follow-up was six months. The implant centered well and resisted capsular shrinkage. Iris touch to the optic was rare and did not provoke persistent pigment dispersion. In one third of the cases a cleft was discernible between the posterior convex IOL surface and the extended capsule despite thorough aspiration of viscoelastic and debris from the retrolental space. In 8% of cases, white flakes of unknown origin were observed at the IOL-capsule interface. In cases associated with pre-existing iritis or intraoperative iris trauma (iris manipulation, iridectomy, or synechiolysis in glaucoma patients), fibrin exudation as well as iridocapsular synechial formation and macrophage precipitation often ensued. Cellular precipitates, as evaluated by biomicroscopy and specular microscopy, were less pronounced and more transient than on poly(methyl methacrylate) IOLs. Best case visual acuity results were comparable to those with conventional implants; all eyes attained 20/40 or better and 97% achieved 20/25 or better. The 1103 was easier to implant through a capsulorhexis opening and suited the dimensions of the capsular bag better than the PC-12 model.Keywords
This publication has 23 references indexed in Scilit:
- Evaluation of 150 consecutive cases of poly HEMA posterior chamber lenses implanted in the bag using a small-incision techniqueJournal of Cataract & Refractive Surgery, 1990
- Displacement of bag-placed hydrogel lenses into the vitreous following neodymium:YAG laser capsulotomyJournal of Cataract & Refractive Surgery, 1990
- Spectrum of Nd:YAG laser-induced intraocular lens damage in explanted lensesJournal of Cataract & Refractive Surgery, 1990
- Physical fixation of soft intraocular lensesJournal of Cataract & Refractive Surgery, 1989
- Neodymium:YAG laser interaction with Alcon IOGEL hydrogel intraocular lenses: An in vitro toxicity assayJournal of Cataract & Refractive Surgery, 1987
- Direct measurement of the capsular bagAmerican Intra-Ocular Implant Society Journal, 1984
- Corneal Endothelial Loss with New Intraocular LensesAmerican Journal of Ophthalmology, 1984
- Complications of intraocular lenses. A historical and histopathological reviewSurvey of Ophthalmology, 1984
- Poly-HEMA as a material for intraocular lens implantation: a preliminary report.British Journal of Ophthalmology, 1981
- Corneal Endothelium Damage with Intraocular Lenses: Contact Adhesion Between Surgical Materials and TissueScience, 1977