Posterior capsule opacification and neodymium:YAG laser capsulotomy rates with a round-edged silicone and a sharp-edged hydrophobic acrylic intraocular lens 10 years after surgery
- 1 March 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 35 (3), 459-465
- https://doi.org/10.1016/j.jcrs.2008.11.044
Abstract
To compare posterior capsule opacification (PCO) and neodymium:YAG (Nd:YAG) laser capsulotomy rates 10 years after surgery between two 3-piece intraocular lenses (IOLs): a silicone IOL with round optic edges and a hydrophobic acrylic IOL with sharp optic edges. Department of Ophthalmology, Medical University of Vienna, Vienna General Hospital, Vienna, Austria. Patients having had cataract surgery and implantation of at least 1 study IOL by the same surgeon between 1994 and 1999 were retrospectively examined. The number of Nd:YAG laser capsulotomies performed was noted. The PCO intensity was assessed using digital retroilluminated photographs and Automated Quantification of After-Cataract (AQUA) software. The AQUA scores in eyes with Nd:YAG capsulotomy were estimated with a multiple-imputation procedure. Anterior capsule opacification (ACO) and fibrotic PCO were graded subjectively at the slitlamp. The study evaluated 143 eyes (98 patients). Eight (18%) of 44 eyes with a silicone IOL and 41 (42%) of 99 eyes with an acrylic IOL had Nd:YAG capsulotomy after 10 years (P = .007). The AQUA scores were lower with the silicone IOLs. The median difference in AQUA scores was significantly different after missing values of the Nd:YAG capsulotomies were imputed. There was no difference in ACO. There was more fibrotic PCO with round-edged silicone IOLs than with sharp-edged acrylic IOLs. Ten years after surgery, acrylic IOLs seemed to lose their PCO preventive effect, despite their sharp optic edges. The increasingly longer life expectancy and earlier cataract surgery mandate reconsideration of preferences regarding optic materials and design elements of IOLs.Keywords
This publication has 27 references indexed in Scilit:
- Ten-Year Incidence of Age-Related Cataract and Cataract Surgery in an Older Australian PopulationOphthalmology, 2007
- Clinical effects of primary posterior continuous curvilinear capsulorhexis in eyes with single-piece hydrophilic acrylic intraocular lenses with and without haptic angulationJournal of Cataract & Refractive Surgery, 2007
- Effect of the hydrophilicity of acrylic intraocular lens material and haptic angulation on anterior capsule opacificationBritish Journal of Ophthalmology, 2006
- The impact of cataract severity on measurement acquisition with the IOLMasterActa Ophthalmologica Scandinavica, 2005
- Effect of intraocular lenses on preventing posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2004
- Five year incidence of cataract surgery: the Blue Mountains Eye StudyBritish Journal of Ophthalmology, 2003
- Comparison of 4 methods for quantifying posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2003
- The Swedish National Cataract Register: A 9‐year reviewActa Ophthalmologica Scandinavica, 2002
- Speed of capsular bend formation at the optic edge of acrylic, silicone, and poly(methyl methacrylate) lensesJournal of Cataract & Refractive Surgery, 2002
- Reproducibility of standardized retroillumination photography for quantification of posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2002