Maximum and Average Urine Flow Rates in Normal Male and Female Populations—the Liverposl Nomograms
- 1 July 1989
- journal article
- research article
- Published by Wiley in British Journal of Urology
- Vol. 64 (1), 30-38
- https://doi.org/10.1111/j.1464-410x.1989.tb05518.x
Abstract
Summary— The study of voiding in men and women has been handicapped by the lack of a normal reference range covering urinary flow rates over a wide range of voided volumes. Normal volunteers (331 males and 249 females) were studied. Each voided once into a calibrated Dantec Urodyn 1000 mictiograph. On a second occasion 282 men and 46 women voided. The maximum and average urine flow rates of the first voids in both sexes were compared with the respective voided volumes. Nomogram charts, in centile form, for both the maximum and average urine flow rates were constructed using statistical transformations of the data. Males showed a significant decline in both urinary flow rates with age, although there was no statistically significant variation in either urine flow rate with respect to first versus repeated voiding. Females showed no statistically significant variation in either urine flow rate with respect to age, parity or first versus repeated voiding. The maximum and average urine flow rates in both sexes showed an equally strong relationship to voided volume. No artificial restriction of voided volume, erg. minimum 200 ml, appeared appropriate. These nomograms offer reference ranges for both maximum and average urinary flow rates in both sexes covering a wide range of voided volumes (15–600 ml).This publication has 18 references indexed in Scilit:
- Obstructed Voiding in the FemaleBritish Journal of Urology, 1988
- UrodynamicsPublished by Springer Nature ,1987
- Urodynamic equipment: technical aspectsJournal of Medical Engineering & Technology, 1987
- Fluid weight uroflowmetry in womenAmerican Journal of Obstetrics and Gynecology, 1983
- The Use of Urinary Flow Rates Obtained from Voided Volumes Less than 150 ml in the Assessment of Voiding AbilityBritish Journal of Urology, 1983
- A Technical and Clinical Evaluation of The Disa UroflowmeterBritish Journal of Urology, 1977
- Second Report on the Standardisation of Terminology of Lower Urinary Tract FunctionScandinavian Journal of Urology and Nephrology, 1977
- A New Recording Uroflometer: A Simple Automatic Device for Measuring Voiding VelocityJournal of Urology, 1957
- The Uroflometer: An Aid to the Study of the Lower Urinary TractJournal of Urology, 1948