Mutant Frequency of Radiotherapy Technicians Appears to Be Associated With Recent Dose of Ionizing Radiation

Abstract
The frequency of hypoxanthine phosphoribosyl transferase (HPRT) mutants among peripheral T-lymphocytes of radiotherapy technicians primarily exposed to 60Co was measured by the T-cell cloning method. Mutant frequencies of these technicians in 1984 and 1986 were significantly higher than those of physiotherapy technicians who worked in a neighboring service, and correlated significantly with thermoluminescence dosimeter readings recorded during the 6 mo preceding mutant frequency determination. Correlations decreased when related to dose recorded over longer time intervals. HPRT mutant frequency determination in peripheral lymphocytes is a good measure of recently received biologically effective radiation dose in an occupationally exposed population.