Abstract
A sensitive specific high-performance liquid chromatographic procedure for the determination of norethindrone in plasma is described. The organic solvent extract from plasma is chromatographed on a reversed phase column using a high-performance liquid chromatograph fitted with an ultraviolet detector (254 nm); quantitation from plasma samples containing 2 ng/ml norethindrone is reported. Metabolites and endogenous substances do not interfere with the assay. The determination of norethindrone concentrations in plasma following administration of single oral dose to a mini-pig is described.