A modified fuzzy c-means algorithm for bias field estimation and segmentation of MRI data
Top Cited Papers
- 7 August 2002
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 21 (3), 193-199
- https://doi.org/10.1109/42.996338
Abstract
We present a novel algorithm for fuzzy segmentation of magnetic resonance imaging (MRI) data and estimation of intensity inhomogeneities using fuzzy logic. MRI intensity inhomogeneities can be attributed to imperfections in the radio-frequency coils or to problems associated with the acquisition sequences. The result is a slowly varying shading artifact over the image that can produce errors with conventional intensity-based classification. Our algorithm is formulated by modifying the objective function of the standard fuzzy c-means (FCM) algorithm to compensate for such inhomogeneities and to allow the labeling of a pixel (voxel) to be influenced by the labels in its immediate neighborhood. The neighborhood effect acts as a regularizer and biases the solution toward piecewise-homogeneous labelings. Such a regularization is useful in segmenting scans corrupted by salt and pepper noise. Experimental results on both synthetic images and MR data are given to demonstrate the effectiveness and efficiency of the proposed algorithm.Keywords
This publication has 25 references indexed in Scilit:
- Optimized homomorphic unsharp masking for MR grayscale inhomogeneity correctionIEEE Transactions on Medical Imaging, 1998
- A nonparametric method for automatic correction of intensity nonuniformity in MRI dataIEEE Transactions on Medical Imaging, 1998
- Estimating the bias field of MR imagesIEEE Transactions on Medical Imaging, 1997
- Adaptive segmentation of MRI dataIEEE Transactions on Medical Imaging, 1996
- Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRIIEEE Transactions on Medical Imaging, 1996
- Retrospective correction of intensity inhomogeneities in MRIIEEE Transactions on Medical Imaging, 1995
- Sources of intensity nonuniformity in spin echo images at 1.5 TMagnetic Resonance in Medicine, 1994
- Polynomial modeling and reduction of RF body coil spatial inhomogeneity in MRIIEEE Transactions on Medical Imaging, 1993
- Correction of intensity variations in MR images for computer-aided tissue classificationIEEE Transactions on Medical Imaging, 1993
- Image non-uniformity in magnetic resonance imaging: its magnitude and methods for its correctionThe British Journal of Radiology, 1987