Evaluation of accelerated iterative x-ray CT image reconstruction using floating point graphics hardware
- 25 January 2006
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (4), 875-889
- https://doi.org/10.1088/0031-9155/51/4/008
Abstract
Statistical reconstruction methods offer possibilities to improve image quality as compared with analytical methods, but current reconstruction times prohibit routine application in clinical and micro-CT. In particular, for cone-beam x-ray CT, the use of graphics hardware has been proposed to accelerate the forward and back-projection operations, in order to reduce reconstruction times. In the past, wide application of this texture hardware mapping approach was hampered owing to limited intrinsic accuracy. Recently, however, floating point precision has become available in the latest generation commodity graphics cards. In this paper, we utilize this feature to construct a graphics hardware accelerated version of the ordered subset convex reconstruction algorithm. The aims of this paper are (i) to study the impact of using graphics hardware acceleration for statistical reconstruction on the reconstructed image accuracy and (ii) to measure the speed increase one can obtain by using graphics hardware acceleration. We compare the unaccelerated algorithm with the graphics hardware accelerated version, and for the latter we consider two different interpolation techniques. A simulation study of a micro-CT scanner with a mathematical phantom shows that at almost preserved reconstructed image accuracy, speed-ups of a factor 40 to 222 can be achieved, compared with the unaccelerated algorithm, and depending on the phantom and detector sizes. Reconstruction from physical phantom data reconfirms the usability of the accelerated algorithm for practical cases.Keywords
This publication has 24 references indexed in Scilit:
- Statistical Image Reconstruction Methods for Transmission TomographyPublished by SPIE-Intl Soc Optical Eng ,2010
- Experimental validation of a rapid Monte Carlo based micro-CT simulatorPhysics in Medicine & Biology, 2004
- Rapid emission tomography reconstructionPublished by Association for Computing Machinery (ACM) ,2003
- Efficient fully 3-D iterative SPECT reconstruction with Monte Carlo-based scatter compensationIEEE Transactions on Medical Imaging, 2002
- Statistical image reconstruction for polyenergetic X-ray computed tomographyIEEE Transactions on Medical Imaging, 2002
- Effect of phantom voxelization in CT simulationsMedical Physics, 2002
- Ordered subset reconstruction for x-ray CTPhysics in Medicine & Biology, 2001
- Comparison of 3-D maximum a posteriori and filtered backprojection algorithms for high-resolution animal imaging with microPETIEEE Transactions on Medical Imaging, 2000
- Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensationIEEE Transactions on Medical Imaging, 1996
- Accelerated volume rendering and tomographic reconstruction using texture mapping hardwarePublished by Association for Computing Machinery (ACM) ,1994