Correction for vascular artifacts in cerebral blood flow values measured by using arterial spin tagging techniques
- 1 February 1997
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 37 (2), 226-235
- https://doi.org/10.1002/mrm.1910370215
Abstract
„Vascular”︁ artifacts can have substantial effects on human cerebral blood flow values calculated by using arterial spin tagging approaches. One vascular artifact arises from the contribution of „tagged”︁ arterial water spins to the observed change in brain water MR signal. This artifact can be reduced if large bipolar gradients are used to „crush”︁ the MR signal from moving arterial water spins. A second vascular artifact arises from relaxation of „tagged”︁ arterial blood during transit from the tagging plane to the capillary exchange site in the imaging slice. This artifact can be corrected if the arterial transit times are measured by using „dynamic”︁ spin tagging approaches. The mean transit time from the tagging plane to capillary exchange sites in a gray matter region of interest was calculated to be ∼0.94 s. Cerebral blood flow values calculated for seven normal volunteers agree reasonably well with values calculated by using radioactive tracer approaches.Keywords
This publication has 17 references indexed in Scilit:
- Perfusion imaging of the human brain at 1.5 T using a single‐shot EPI spin tagging approachMagnetic Resonance in Medicine, 1996
- Perfusion imaging with compensation for asymmetric magnetization transfer effectsMagnetic Resonance in Medicine, 1996
- Comparison of t2 relaxation in blood, brain, and ferritinJournal of Magnetic Resonance Imaging, 1995
- Tissue specific perfusion imaging using arterial spin labelingNMR in Biomedicine, 1994
- Radioactive microsphere validation of a volume localized continuous saturation perfusion measurementMagnetic Resonance in Medicine, 1994
- Quantitative magnetic resonance imaging of human brain perfusion at 1.5 T using steady-state inversion of arterial water.Proceedings of the National Academy of Sciences, 1994
- Magnetic resonance imaging of perfusion using spin inversion of arterial water.Proceedings of the National Academy of Sciences, 1992
- Perfusion imagingMagnetic Resonance in Medicine, 1992
- Projection angiograms of blood labeled by adiabatic fast passageMagnetic Resonance in Medicine, 1986
- What is the Correct Value for the Brain-Blood Partition Coefficient for Water?Journal of Cerebral Blood Flow & Metabolism, 1985