Capsular bag stability and posterior capsule opacification of a plate-haptic design microincision cataract surgery intraocular lens: 3-year results of a randomised trial
- 24 September 2013
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 97 (12), 1565-1568
- https://doi.org/10.1136/bjophthalmol-2013-303710
Abstract
To compare capsular bag stability and posterior capsule opacification (PCO) of a plate-haptic intraocular lens (IOL) and a standard three-piece open-loop-haptic IOL of the same acrylic material. In this randomised bilateral patient-masked and examiner-masked study, each patient received a microincision cataract surgery IOL (MICS IOL; Acri.Smart 46S=CT SHERIS 209M) in one eye and a small incision cataract surgery IOL (SICS IOL; AcriLyc 53N = CT 53N, both Carl Zeiss Meditec AG, Germany) as a control in the contralateral eye. Follow-up examinations were performed 1 h, 1 week, 1 month, 1 year and 3 years postoperatively. Anterior chamber depth (ACD) was measured and retroillumination images were performed at all postoperative follow-ups. Furthermore, uncorrected and corrected distance visual acuity, autorefraction and subjective refraction were assessed. In total, 50 eyes of 25 patients were included. The ACD difference between the MICS IOL and the SICS IOL was not significant at any time point (p>0.05). Distance-corrected visual acuity at the 3-year follow-up was similar and not significantly different between the groups (p=0.48). Mean AQUA score in the MICS IOL group and in the SICS IOL group at the 3-year follow-up was 2.3 (SD ±2.3) and 2.1 (SD ±2.2), respectively (p=0.79). The investigated hydrophilic acrylic plate-haptic MICS IOL with a hydrophobic surface showed comparable results concerning capsular bag stability and PCO rates up to 3 years compared with a SICS IOL of the same material.Keywords
This publication has 17 references indexed in Scilit:
- Rotational stability and posterior capsule opacification of a plate-haptic and an open-loop-haptic intraocular lensJournal of Cataract & Refractive Surgery, 2011
- Vergleich von 4 MICS-Intraokularlinsen im Hinblick auf ihre Neodym:YAG-Laser-KapsulotomieratenKlinische Monatsblätter für Augenheilkunde, 2010
- Effect of intraocular lens design on posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2008
- Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lensesJournal of Cataract & Refractive Surgery, 2008
- Edge profile of commercially available square-edged intraocular lensesJournal of Cataract & Refractive Surgery, 2008
- Long-term Effect of 1-Piece and 3-Piece Hydrophobic Acrylic Intraocular Lens on Posterior Capsule Opacification: A Randomized TrialOphthalmology, 2007
- Advances in microincision cataract surgery intraocular lensesCurrent Opinion in Opthalmology, 2006
- Scanning electron microscopic analysis of acrylic intraocular lenses for microincision cataract surgeryJournal of Cataract & Refractive Surgery, 2006
- Visual outcome of microincision cataract surgery with implantation of an Acri.Smart lensJournal of Cataract & Refractive Surgery, 2005
- Langzeitergebnisse nach Implantation einer Plattenhaptik-Silikonlinse in den KapselsackKlinische Monatsblätter für Augenheilkunde, 1994