Marine Bacteria Cause False-Positive Results in the Colilert-18 Rapid Identification Test for Escherichia coli in Florida Waters
Open Access
- 1 February 2002
- journal article
- research article
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 68 (2), 7454
- https://doi.org/10.1128/aem.68.2.539-544.2002
Abstract
The Colilert-18 system for enumeration of total coliforms and Escherichia coli is approved by the U.S. Environmental Protection Agency for use in drinking water analysis and is also used by various agencies and research studies for enumeration of indicator organisms in fresh and saline waters. During monitoring of Pinellas County, Fla., marine waters, estimates of E. coli numbers (by Colilert-18) frequently exceeded fecal coliform counts (by membrane filtration) by 1 to 3 orders of magnitude. Samples from freshwater sites did not display similar discrepancies. Fecal coliforms, including E. coli, could be cultured from 100% of yellow fluorescent wells (denoting E. coli-positive results) inoculated with freshwater samples but could be cultured from only 17.1% of the "positive" wells inoculated with marine samples. Ortho-nitrophenyl-beta-D-galactopyranoside (ONPG)-positive or 4-methylumbelliferyl-beta-D-glucuronide (MUG)-positive noncoliform bacteria were readily cultured from Colilert-18 test wells inoculated with marine samples. Filtered cell-free seawater did not cause false positives. Coculture preparations of as few as 5 CFU of Vibrio cholerae (ONPG positive) and Providencia sp. (MUG positive) ml(-1) inoculated into Colilert-18 caused false-positive E. coli results. Salinity conditions influenced coculture results, as the concentration of coculture inoculum required to cause false positives in most wells increased from about 5 CFU ml(-1) in seawater diluted 1:10 with freshwater to approximately equal to 5,000 CFU ml(-1) in seawater diluted 1:20 with freshwater. Estimated E. coli numbers in various marine water samples processed at the 1:10 dilution ranged from 10 to 7,270 CFU.100 ml(-1), while E. coli numbers in the same samples processed at the 1:20 dilution did not exceed 40 CFU.100 ml(-1). The lower estimates of E. coli numbers corresponded well with fecal coliform counts by membrane filtration. This study indicates that assessment of E. coli in subtropical marine waters by Colilert-18 is not accurate when the recommended 1:10 sample dilution is used. The results suggest that greater dilution may diminish the false-positive problem, but further study of this possibility is recommended.Keywords
This publication has 42 references indexed in Scilit:
- Quantitative determination of total coliforms and Escherichia coli in marine waters with chromogenic and fluorogenic mediaJournal of Applied Microbiology, 2000
- Sources of Escherichia coli in a Coastal Subtropical EnvironmentApplied and Environmental Microbiology, 2000
- False‐positive coliform reaction mediated by Aeromonas in the Colilert defined substrate technology systemLetters in Applied Microbiology, 1998
- Use of two presence/absence systems for the detection of E. coli and coliforms from waterWater Research, 1996
- Possible interference of lactose‐fermenting marine vibrios in coliform ‐D‐galactosidase assaysJournal of Applied Bacteriology, 1995
- Evaluation of β-glucuronidase assay for the detection of Escherichia coli from environmental watersCanadian Journal of Microbiology, 1991
- Proportion of beta-D-glucuronidase-negative Escherichia coli in human fecal samplesApplied and Environmental Microbiology, 1989
- A note on starch hydrolysis and β‐glucuronidase activity among flavobacteriaJournal of Applied Bacteriology, 1986
- Methylumbelliferyl-beta-D-glucuronide-based medium for rapid isolation and identification of Escherichia coliJournal of Clinical Microbiology, 1984
- Rapid Identification of EnterobacteriaceaeActa Pathologica Microbiologica Scandinavica Section B Microbiology, 1979