The Clinical Utility of Dynamic Contour Tonometry and Ocular Pulse Amplitude
- 1 December 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 16 (8), 700-703
- https://doi.org/10.1097/ijg.0b013e31806ab2fe
Abstract
Purpose To determine if ocular pulse amplitude (OPA) as measured by dynamic contour tonometry (DCT) is related to severity of glaucoma, and if intraocular pressure (IOP) as measured by DCT is related to central corneal thickness (CCT). Methods Patients were selected from the Duke Eye Center glaucoma clinic. Fifty-five eyes of 32 patients were included; right and left eyes were analyzed separately. CCT, OPA, DCT IOP, Goldmann applanation tonometry (GAT), Tonopen applanation tonometry (TAT), and systemic blood pressure were measured. Advanced Glaucoma Intervention Study score and mean deviation of visual field, and vertical and horizontal cup-disc ratios were recorded in a masked manner. Descriptive statistics were obtained, and OPA, DCT IOP, GAT, and TAT underwent univariate analyses to assess for relationships with predictor variables. Results OPA, DCT IOP, GAT, and TAT were positively associated with CCT and with having no surgical intervention for right and left eyes, and were negatively associated with vertical and horizontal cup-disc ratios. Conclusions Increased OPA seems to correlate with less severe glaucoma and with increased CCT. DCT IOP seems to be affected by CCT along with GAT and TAT.Keywords
This publication has 33 references indexed in Scilit:
- Ocular Pulse Amplitude in Healthy Subjects as Measured by Dynamic Contour TonometryArchives of Ophthalmology (1950), 2006
- Dynamic Contour TonometryJournal of Glaucoma, 2005
- Dynamic Contour Tonometry for Intraocular Pressure MeasurementAmerican Journal of Ophthalmology, 2005
- Comparison of intraocular pressure measured by Pascal dynamic contour tonometry and Goldmann applanation tonometryEye, 2005
- Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration statesAlbrecht von Graefes Archiv für Ophthalmologie, 2004
- Increased ocular pulse amplitude revealing aortic regurgitationAmerican Journal of Ophthalmology, 2004
- Comparison of Dynamic Contour Tonometry with Goldmann Applanation TonometryInvestigative Opthalmology & Visual Science, 2004
- Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIKJournal of Cataract & Refractive Surgery, 2004
- Intraocular Pressure Measurements Using Dynamic Contour Tonometry after Laser In Situ KeratomileusisInvestigative Opthalmology & Visual Science, 2003
- Advanced Glaucoma Intervention StudyOphthalmology, 1994