A tracking FFT processor for pulsed Doppler analysis beyond the Nyquist limit (medical ultrasound)
- 1 January 1989
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 36 (2), 232-237
- https://doi.org/10.1109/10.16470
Abstract
A tracking procedure for processing ultrasound pulsed Doppler signals with instantaneous frequencies beyond the Nyquist limit is discussed. It is based on the observation that the frequency translation required to properly reconstruct an aliased spectrum can be achieved by means of a simple reordering of data provided by a digital fast Fourier transform (FFT) unit. The amount of reordering is automatically derived by the computed value of a spectral parameter, e.g., the mean frequency. The procedure has been tested by introducing some modifications at the output of an FFT unit included in a conventional pulsed Doppler system. As a result, the dynamic evolution of the full Doppler spectrum and related mean frequency can be followed in real time over an extended range. In vitro and in vivo experiments, as well as quantitative measurements carried on with test signals are presented.Keywords
This publication has 11 references indexed in Scilit:
- A high-speed FFT unit based on a low cost digital signal processorIEEE Transactions on Circuits and Systems, 1988
- Angle Independent Ultrasonic Detection of Blood FlowIEEE Transactions on Biomedical Engineering, 1987
- A New Velocity Estimator for Color Flow MappingPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1986
- A Comparison Between Mean Frequency Estimators for Multigated Doppler Systems with Serial Signal ProcessingIEEE Transactions on Biomedical Engineering, 1985
- Doppler developments in the last quinquenniumJapanese Journal of Clinical Oncology, 1985
- The Accurate Ultrasonic Measurement of the Volume Flow of Blood by Time Domain CorrelationPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1985
- A Novel Frequency Estimator for Sampled Doppler SignalsIEEE Transactions on Biomedical Engineering, 1984
- Software analysis of 20 mhz pulsed doppler quadrature dataJapanese Journal of Clinical Oncology, 1983
- Discrete Time Estimation of the Mean Doppler Frequency in Ultrasonic Blood Velocity MeasurementsIEEE Transactions on Biomedical Engineering, 1983
- On increasing the range of pulsed Doppler systems for blood flow measurementJapanese Journal of Clinical Oncology, 1980