Use of radiofrequency current to ablate accessory connections in children.
- 1 December 1991
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 84 (6), 2318-2324
- https://doi.org/10.1161/01.cir.84.6.2318
Abstract
BACKGROUND Several investigators have recently ablated electrophysiologically mapped accessory connections in the adult human myocardium by using radiofrequency current. To examine the effectiveness and safety of radiofrequency current for ablation of accessory connections in children, 20 consecutive patients (age, 3-18 years) with preexcitation and/or supraventricular tachycardia were evaluated by electrophysiological study. METHODS AND RESULTS Nineteen of the 20 patients were completely studied and demonstrated accessory connections. After identification of the earliest retrograde atrial activation site, a steerable 7F catheter (with a 4-mm-long electrode at the distal tip) was placed within the ventricular cavity ipsilateral to the accessory connection and positioned at the atrioventricular valve annulus directly opposite the earliest point of retrograde atrial activation. Radiofrequency current was delivered at 50-65 volts for 10-60 seconds at a frequency of 500 kHz. Radiofrequency pulses were delivered for two to 26 trials. Upon completion of radiofrequency trials, repeat electrophysiological testing was performed. Thirteen of 19 subjects (68%) experienced definite successful ablation of their accessory pathway; an additional patient had probable successful ablation, yielding an overall success rate of 74%. Eighty-seven percent of individuals with a left-sided pathway had permanent ablation and 100% with a manifest left-sided pathway experienced successful ablation. Only 29% of the first seven patients had a successful result; in contrast, 92% of the next 12 patients had successful interruption of their accessory pathways. After ablation, 4-day continuous electrocardiographic telemetry disclosed no significant arrhythmias. CPK enzyme rises peaked at 12-24 hours. The rise was excessive and associated with general anesthesia in five patients. The isoenzyme MB fraction rose mildly in five other patients and returned to normal within 72 hours. No clinical or electrocardiographic evidence of myocardial ischemia was detected. Follow-up for 4-12 months indicates no return of preexcitation or tachycardia in any patient whose accessory connection was successfully ablated. CONCLUSIONS This experience indicates that radiofrequency current is an effective and safe technique for ablation of accessory connections in children.Keywords
This publication has 14 references indexed in Scilit:
- Incidence and clinical significance of transient creatine kinase elevations and the diagnosis of non-Q wave myocardial infarction associated with coronary angioplastyJournal of the American College of Cardiology, 1991
- Transcatheter Electrical Ablation of Accessory Pathways in ChildrenPacing and Clinical Electrophysiology, 1989
- Surgical management of children and young adults with the Wolff-Parkinson-White syndromeHeart and Vessels, 1988
- Comparison of single and double balloon valvuloplasty in children with aortic stenosisJournal of the American College of Cardiology, 1988
- High frequency alternating current ablation of an accessory pathway in humansJournal of the American College of Cardiology, 1987
- Balloon dilation of the aortic valve: Studies in normal lambs and in children with aortic stenosisJournal of the American College of Cardiology, 1987
- Masseter Spasm with AnesthesiaAnesthesiology, 1984
- Cardiac Arrhythmias in ChildrenAnnual Review of Medicine, 1984
- Evaluation of Myocardial Damage in Patients Undergoing Coronary-Artery Bypass Procedures with Halothane-N2O Anesthesia and AdjuvantsAnesthesia & Analgesia, 1977