Dual-Modality Imaging of Cancer with SPECT/CT
Open Access
- 1 December 2002
- journal article
- research article
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 1 (6), 449-458
- https://doi.org/10.1177/153303460200100605
Abstract
Dual-modality imaging is an in vivo diagnostic technique that obtains structural and functional information directly from patient studies in a way that cannot be achieved with separate imaging systems alone. Dual-modality imaging systems are configured by combining computed tomography (CT) with radionuclide imaging (using positron emission tomography (PET) or single-photon emission computed tomography (SPECT)) on a single gantry which allows both functional and structural imaging to be performed during a single imaging session without having the patient leave the imaging system. A SPECT/CT system developed at UCSF is being used in a study to determine if dual-modality imaging offers advantages for assessment of patients with prostate cancer using111 In-ProstaScint®, a radiolabeled antibody for the prostate-specific membrane antigen.111 In-ProstaScint® images are reconstructed using an iterative maximum-likelihood expectation-maximization (ML-EM) algorithm with correction for photon attenuation using a patient-specific map of attenuation coefficients derived from CT. The ML-EM algorithm accounts for the dual-photon nature of the111 In-labeled radionuclide, and incorporates correction for the geometric response of the radionuclide collimator. The radionuclide image then can be coregistered and overlaid in color on a grayscale CT image for improved localization of the functional information from SPECT. Radionuclide images obtained with SPECT/CT and reconstructed using ML-EM with correction for photon attenuation and collimator response improve image quality in comparison to conventional radionuclide images obtained with filtered backprojection reconstruction. These results illustrate the potential advantages of dual-modality imaging for improving the quality and the localization of radionuclide uptake for staging disease, planning treatment, and monitoring therapeutic response in patients with cancer.Keywords
This publication has 39 references indexed in Scilit:
- Absolute in vivo quantitation of myocardial activityIEEE Transactions on Nuclear Science, 2000
- Positron emission tomography with 18fluorine‐labelled deoxyglucose: utility in localized and advanced prostate cancerBJU International, 1999
- Design of a small animal MR compatible PET scannerIEEE Transactions on Nuclear Science, 1999
- Preliminary Imaging Results Using In-111 Labeled CYT-356 (Prostascintst) in the Detection of Recurrent Prostate CancerClinical Nuclear Medicine, 1996
- Attenuation correction of SPECT using X-ray CT on an emission-transmission CT system: myocardial perfusion assessmentIEEE Transactions on Nuclear Science, 1996
- A proton profile monitor using an amorphous silicon photodiode arrayIEEE Transactions on Nuclear Science, 1993
- Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensionsPhysics in Medicine & Biology, 1992
- CT-SPECT fusion for analysis of radiolabeled antibodies: Applications in gastrointestinal and lung carcinomaInternational Journal of Radiation Applications and Instrumentation. Part B. Nuclear Medicine and Biology, 1991
- Three-dimensional iterative reconstruction algorithms with attenuation and geometric point response correctionIEEE Transactions on Nuclear Science, 1991
- Quantitative SPECT by attenuation correction of the projection set using transmission data: evaluation of a methodEuropean Journal of Nuclear Medicine and Molecular Imaging, 1990