Chemically reactive metabolites may cause hepatotoxicity and as a result liver failure or other adverse side reactions. Therefore, this is a vital topic of interest because early reactive metabolite screening may prevent compound failure at a later stage. In order to address this issue, a screening assay has been developed to detect the formation of reactive metabolites by using glutathione as a trapping reagent, which will allow us to search for phase I metabolites and also glutathiones during in vitro metabolite screening using liquid chromatography/tandem mass spectrometry (LC/MS/MS) with exact mass. Glutathione conjugations when fragmented by the mass spectrometer give a common loss corresponding to the pyroglutamic acid moiety, which can be monitored. Until recently, this work has been carried out with triple quadrupole technology using nominal mass. The advantage of the hybrid quadrupole time‐of‐flight mass spectrometer is the selectivity and sensitivity that can be achieved. Exact neutral loss detection is achieved via sequential low‐ and high‐energy MS acquisitions. After detection of the loss of the pyroglutamic acid moiety, using a window of ±20 mDa on the high‐energy scan, MS/MS is carried out on the parent mass of interest to confirm the common neutral loss. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 22 references indexed in Scilit:
- Drug−Protein Adducts: An Industry Perspective on Minimizing the Potential for Drug Bioactivation in Drug Discovery and DevelopmentChemical Research in Toxicology, 2003
- Addressing the metabolic activation potential of new leads in drug discovery: a case study using ion trap mass spectrometry and tritium labeling techniquesJournal of Mass Spectrometry, 2003
- Reactive metabolites and their role in drug reactionsCurrent Opinion in Allergy and Clinical Immunology, 2001
- Biological Reactive Intermediates in Drug Discovery and DevelopmentPublished by Springer Nature ,2001
- Advances in molecular toxicology–towards understanding idiosyncratic drug toxicityToxicology, 2000
- Incidence of Adverse Drug Reactions in Hospitalized PatientsJAMA, 1998
- Reactive metabolites and agranulocytosisEuropean Journal of Haematology, 1996
- Mass spectrometry in the analysis of glutathione conjugatesJournal of Mass Spectrometry, 1993
- Off-line liquid chromatographic fast atom bombardment tandem mass spectrometric analysis of two diastereomeric glutathione conjugates of α-bromoisovaleryl ureaJournal of Mass Spectrometry, 1988
- Comparative electron impact, chemical ionization and field desorption mass spectra of some thioether metabolites of acetaminophenJournal of Mass Spectrometry, 1981