Effect of Finger Posture on the Tendon Force Distribution Within the Finger Extensor Mechanism

Abstract
Understanding the transformation of tendon forces into joint torques would greatly aid in the investigation of the complex temporal and spatial coordination of multiple muscles in finger movements. In this study, the effects of the finger posture on the tendon force transmission within the finger extensor apparatus were investigated. In five cadaver specimens, a constant force was applied sequentially to the two extrinsic extensor tendons in the index finger, extensor digitorum communis and extensor indicis proprius. The responses to this loading, i.e., fingertip force/moment and regional strains of the extensor apparatus, were measured and analyzed to estimate the tendon force transmission into the terminal and central slips of the extensor hood. Repeated measures analysis of variance revealed that the amount of tendon force transmitted to each tendon slip was significantly affected by finger posture, specifically by the interphalangeal (IP) joint angles (p30%) when the IP joints were extended. The ratio of terminal slip force:central slip force remained relatively constant across postures at approximately 1.7:1. Force dissipation into surrounding structures was found to be largely responsible for the observed force-posture relationship. Due to the significance of posture in the force transmission to the tendon slips, the impact of finger posture should be carefully considered when studying finger motor control or examining injury mechanisms in the extensor apparatus.