Volumetric modulated arc therapy: IMRT in a single gantry arc
Top Cited Papers
- 26 December 2007
- journal article
- Published by Wiley in Medical Physics
- Vol. 35 (1), 310-317
- https://doi.org/10.1118/1.2818738
Abstract
In this work a novel plan optimization platform is presented where treatment is delivered efficiently and accurately in a single dynamically modulated arc. Improvements in patient care achieved through image-guided positioning and plan adaptation have resulted in an increase in overall treatment times. Intensity-modulated radiation therapy (IMRT) has also increased treatment time by requiring a larger number of beam directions, increased monitor units (MU), and, in the case of tomotherapy, a slice-by-slice delivery. In order to maintain a similar level of patient throughput it will be necessary to increase the efficiency of treatment delivery. The solution proposed here is a novel aperture-based algorithm for treatment plan optimization where dose is delivered during a single gantry arc of up to 360 deg. The technique is similar to tomotherapy in that a full 360 deg of beam directions are available for optimization but is fundamentally different in that the entire dose volume is delivered in a single source rotation. The new technique is referred to as volumetric modulated arc therapy (VMAT). Multileaf collimator (MLC) leaf motion and number of MU per degree of gantry rotation is restricted during the optimization so that gantry rotation speed, leaf translation speed, and dose rate maxima do not excessively limit the delivery efficiency. During planning, investigators model continuous gantry motion by a coarse sampling of static gantry positions and fluence maps or MLC aperture shapes. The technique presented here is unique in that gantry and MLC position sampling is progressively increased throughout the optimization. Using the full gantry range will theoretically provide increased flexibility in generating highly conformal treatment plans. In practice, the additional flexibility is somewhat negated by the additional constraints placed on the amount of MLC leaf motion between gantry samples. A series of studies are performed that characterize the relationship between gantry and MLC sampling, dose modeling accuracy, and optimization time. Results show that gantry angle and MLC sample spacing as low as 1 deg and 0.5 cm, respectively, is desirable for accurate dose modeling. It is also shown that reducing the sample spacing dramatically reduces the ability of the optimization to arrive at a solution. The competing benefits of having small and large sample spacing are mutually realized using the progressive sampling technique described here. Preliminary results show that plans generated with VMAT optimization exhibit dose distributions equivalent or superior to static gantry IMRT. Timing studies have shown that the VMAT technique is well suited for on-line verification and adaptation with delivery times that are reduced to approximately 1.5-3 min for a 200 cGy fraction.Keywords
This publication has 27 references indexed in Scilit:
- Direct aperture optimization for online adaptive radiation therapyMedical Physics, 2007
- An arc-sequencing algorithm for intensity modulated arc therapyMedical Physics, 2007
- An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancerInternational Journal of Radiation Oncology*Biology*Physics, 2005
- Adaptive radiation therapy for compensation of errors in patient setup and treatment deliveryMedical Physics, 2004
- Inverse planning for intensity-modulated arc therapy using direct aperture optimizationPhysics in Medicine & Biology, 2003
- Motion adaptive x-ray therapy: a feasibility studyPhysics in Medicine & Biology, 2000
- Adaptive radiation therapyPhysics in Medicine & Biology, 1997
- Initial Clinical Experience with the Peacock Intensity Modulation of a 3-D Conformal Radiation Therapy SystemStereotactic and Functional Neurosurgery, 1996
- Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapyPhysics in Medicine & Biology, 1995
- Tomotherapy: A new concept for the delivery of dynamic conformal radiotherapyMedical Physics, 1993