Radiation Dose Consideration in Kidney Stone CT Examinations: Integration of Iterative Reconstruction Algorithms With Routine Clinical Practice
- 1 May 2015
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 204 (5), 1055-1063
- https://doi.org/10.2214/ajr.14.13038
Abstract
The objective of our study was to evaluate three commercially available iterative reconstruction (IR) algorithms-ASiR, iDOSE, and SAFIRE-and conventional filtered back projection (FBP) on image quality and radiation dose in kidney stone CT examinations.During the 6-month study period, 684 unenhanced kidney stone CT examinations of consecutive adults were performed on 17 CT scanners (GE Healthcare [vendor 1], n = 12 scanners; Philips Healthcare [vendor 2], n = 2; Siemens Health-care [vendor 3], n = 3); these examinations were retrieved using dose-monitoring software (eXposure). A total of 347 kidney stone CT examinations were reconstructed using FBP, and 337 examinations were processed using IR (ASiR, n = 248; iDOSE, n = 50; SAFIRE, n = 39). The standard-dose scanning parameters for FBP scanners included a tube potential of 120 kVp, a tube current of 75-450 mA for vendor 1 and a Quality Reference mAs of 160-180 for vendor 3, and a slice thickness of 2.5 or 5 mm. The dose-modified protocol for the IR scanners included a higher noise index (1.4 times higher than the standard-dose FBP protocol) for vendor 1, a lower reference tube current-exposure time product for vendor 2 (150 reference mAs), and a lower Quality Reference mAs for vendor 3 (120 Quality Reference mAs). Three radiologists independently reviewed 60 randomly sampled kidney stone CT examinations for image quality, noise, and artifacts. Objective noise and attenuation were also determined. Size-specific dose estimates (SSDEs) were compared using ANOVA.Significantly higher subjective and objective measurements of image noise were found in FBP examinations compared with dose-modified IR examinations (p < 0.05). The radiation dose was substantially lower for the dose-modified IR examinations than the standard-dose FBP examinations (mean SSDE ± SD: 8.1 ± 3.8 vs 11.6 ± 3.6 mGy, respectively) (p < 0.0001), but the radiation dose was comparable among the three IR techniques (ASiR, 7.8 ± 3.1 mGy; iDOSE, 7.5 ± 1.9 mGy; SAFIRE, 7.6 ± 3.2 mGy) (p > 0.05).The three IRs enable 20-33% radiation dose reduction in kidney stone CT examinations compared with the FBP technique without any image quality concerns. The radiation dose and image quality were comparable among these three IR algorithms.Keywords
This publication has 58 references indexed in Scilit:
- Prevalence of Kidney Stones in the United StatesEuropean Urology, 2012
- New and Evolving Concepts in the Imaging and Management of Urolithiasis: Urologists’ PerspectiveRadioGraphics, 2010
- The impact of new methods of imaging on radiation dosage delivered to patientsCurrent Opinion in Urology, 2010
- Imaging in Diagnosis, Treatment, and Follow-Up of Stone PatientsAdvances in Chronic Kidney Disease, 2009
- Evaluation of Suspected Renal Colic with Noncontrast CT in the Emergency Department: A Single Institution StudyJournal of Endourology, 2008
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- Epidemiology and Risk Factors in UrolithiasisUrologia Internationalis, 2007
- Unenhanced helical computed tomography in the evaluation of acute flank painInternational Journal of Urology, 2003
- CT in Detecting Urinary Tract Calculi: Influence on Patient Imaging and Clinical OutcomesRadiology, 2002
- Sensitivity and value of digital CT scout radiography for detecting ureteral stones in patients with ureterolithiasis diagnosed on unenhanced CT.American Journal of Roentgenology, 1999