Integrated System for High-Throughput Protein Identification Using a Microfabricated Device Coupled to Capillary Electrophoresis/Nanoelectrospray Mass Spectrometry
- 1 April 2001
- journal article
- Published by SAGE Publications in European Journal of Mass Spectrometry
- Vol. 7 (2), 143-155
- https://doi.org/10.1255/ejms.399
Abstract
An integrated microsystem providing rapid analyses of trace-level tryptic digests for proteomics application is presented. This modular microsystem includes an autosampler and a microfabricated device comprising a sample introduction port and an array of separation channels together with a low dead-volume facility enabling an interface to nanoelectrospray mass spectrometry. Sequential injection and separation of peptide standards and tryptic digests was achieved with a throughput of up to 30 samples per hour with less than 3% sample carryover. Replicate injections of peptide mixtures indicated that reproducibility of migration time was typically better than 2.3% relative standard deviation (RSD), whereas RSD values of 3.7–11.8% were observed on peak height. Mass spectral detection of sub-micromolar protein digests (< 7 fmol per injection) was achieved using a quadrupole/time-of-flight instrument in less than 2 min per sample with peak widths of 1.8–7.0 s. The analytical potential of this integrated device for the identification of gel-isolated proteins from Neisseria meningitidis immunotype L3 has been demonstrated using both peptide mass-fingerprint database searching and on-line tandem mass spectrometry.Keywords
This publication has 34 references indexed in Scilit:
- Proteomics: Capacityversus utilityElectrophoresis, 2000
- Reliable automatic protein identification from matrix-assisted laser desorption/ionization mass spectrometric peptide fingerprintsElectrophoresis, 1999
- A post-genomic challenge: learning to read patterns of protein synthesisNature, 1999
- Proteomics and automationElectrophoresis, 1999
- Rapid protein identification using a microscale electrospray LC/MS system on an ion trap mass spectrometerJournal of the American Society for Mass Spectrometry, 1998
- Sequence tag identification of intact proteins by matching tanden mass spectral data against sequence data bases.Proceedings of the National Academy of Sciences, 1996
- Error-Tolerant Identification of Peptides in Sequence Databases by Peptide Sequence TagsAnalytical Chemistry, 1994
- An approach to correlate tandem mass spectral data of peptides with amino acid sequences in a protein databaseJournal of the American Society for Mass Spectrometry, 1994
- Peptide Mass Maps: A Highly Informative Approach to Protein IdentificationAnalytical Biochemistry, 1993
- Use of mass spectrometric molecular weight information to identify proteins in sequence databasesJournal of Mass Spectrometry, 1993