Retinal image quality after microincision intraocular lens implantation
- 1 August 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 31 (8), 1557-1560
- https://doi.org/10.1016/j.jcrs.2005.01.026
Abstract
To evaluate the modulation-transfer function (MTF) in eyes implanted with a conventional intraocular lens (IOL) and 2 IOLs designed for microincision cataract surgery (MICS). Research, Development, and Innovation Department, Instituto Oftalmológico de Alicante, Alicante, Spain. This prospective nonrandomized consecutive series comprised 30 eyes implanted with 1 of the following IOLs: conventional acrylic foldable (AcrySof MA60BM, Alcon Laboratories) or the UltraChoice 1.0 ThinOptX (ThinOptX Inc.) or the Acri. Smart 48S (Acri.Tech) MICS IOL. The 0.5 MTF and 0.1 MTF following MICS were calculated 3 months after implantation with the Optical Quality Analysis System (OQAS) for a 5 mm pupil. The differences were statistically analyzed with the Mann-Whitney U test. The values of 0.5 MTF for AcrySof, UltraChoice, ThinOptX, and Acri. Smart IOLs were, respectively, 2.647 cycles per degree (cpd) +/- 0.833 (SD), 2.601 +/- 0.986 cpd, and 3.453 +/- 0.778 cpd. The mean 0.1 MTF values for the same IOLs were 8.720 +/- 3.074 cpd, 8.814 +/- 4.380 cpd, and 11.418 +/- 2.574 cpd, respectively. Statistical analysis did not show significant differences in 0.5 MTF and 0.1 MTF between the conventional IOL and MICS IOLs. Microincision cataract surgery IOLs showed excellent MTF performance when implanted after cataract surgery, equal to that of conventional IOLs. An in vivo MTF study may be an excellent option to evaluate IOL performance in the eye.Keywords
This publication has 6 references indexed in Scilit:
- Corneal Optical Aberrations and Retinal Image Quality in Patients in Whom Monofocal Intraocular Lenses Were ImplantedArchives of Ophthalmology (1950), 2002
- Contributions of the cornea and the lens to the aberrations of the human eyeOptics Letters, 1998
- Presbyopia and the optical changes in the human crystalline lens with ageVision Research, 1998
- Through focus image quality of eyes implanted with monofocal and multifocal intraocular lensesOptical Engineering, 1995
- Modulation transfer functions of eyes implanted with intraocular lensesApplied Optics, 1993
- Determination of the point-spread function of human eyes using a hybrid optical–digital methodJournal of the Optical Society of America A, 1987