Abstract
Part I. Method of displacement.—This method permits the determination of glancing-angles in terms of linear measurements only. It consists in letting a properly limited beam of x-rays, after reflection, fall on a photographic plate placed successively in two parallel positions which differ in distance from the crystal by a known amount. The theory of the method and its practical application to the present case are briefly discussed with references to Uhler's paper.