Abstract
Beneficial effects of nitroprusside infusion in heart failure are purportedly a result of decreased afterload through “impedance” reduction. To study the effect of nitroprusside on vascular factors that determine the total load opposing left ventricular ejection, the total aortic input impedance spectrum was examined in 12 patients with heart failure (cardiac index 20 mm Hg). This input impedance spectrum expresses both mean flow (resistance) and pulsatile flow (compliance and wave reflections) components of vascular load. Aortic root blood flow velocity and pressure were recorded continuously with a catheter-tip electromagnetic velocity probe in addition to left ventricular pressure. Small doses of nitroprusside (9-19 μg/min) altered the total aortic input impedance spectrum as significant (P < 0.05) reductions in both mean and pulsatile components were observed within 60-90 s. With these acute changes in vascular load, left ventricular end diastolic pressure declined (44%) and stroke volume increased (20%, both P < 0.05). Larger nitroprusside doses (20-38 μg/min) caused additional alteration in the aortic input impedance spectrum with further reduction in left ventricular end diastolic pressure and increase in stroke volume but no additional changes in the impedance spectrum or stroke volume occurred with 39-77 μg/min. Improved ventricular function persisted when aortic pressure was restored to control values with simultaneous phenylephrine infusion in three patients. These data indicate that nitroprusside acutely alters both the mean and pulsatile components of vascular load to effect improvement in ventricular function in patients with heart failure. The evidence presented suggests that it may be possible to reduce vascular load and improve ventricular function independent of aortic pressure reduction.This publication has 23 references indexed in Scilit:
- Instantaneous blood flow responses to positive end-expiratory pressure with spontaneous ventilation.Circulation, 1979
- Percutaneous left ventricular catheterisation with an ultraminiature catheter-tip pressure transducerCardiovascular Research, 1978
- Aortic input impedance in heart failure.Circulation, 1978
- Instantaneous force-velocity-length relations in the intact human heartThe American Journal of Cardiology, 1977
- Input impedance of the systemic circulation in man.Circulation Research, 1977
- The role of vasodilator therapy in heart failureProgress in Cardiovascular Diseases, 1977
- Reflection in the systemic arterial system: effects of aortic and carotid occlusionCardiovascular Research, 1976
- Effects of Alterations in Aortic Impedance on the Performance of the VentriclesCirculation Research, 1964
- Relation Between Pressure and Diameter in the Ascending Aorta of ManCirculation Research, 1962
- Hemodynamic Determinants of Oxygen Consumption of the Heart With Special Reference to the Tension-Time IndexAmerican Journal of Physiology-Legacy Content, 1957