Local delivery of dexamethasone for prevention of neointimal proliferation in a rat model of balloon angioplasty.
Open Access
- 1 March 1994
- journal article
- Published by American Society for Clinical Investigation in Journal of Clinical Investigation
- Vol. 93 (3), 1243-1249
- https://doi.org/10.1172/jci117078
Abstract
A periadventitial polymer system is an alternative local drug delivery technique to obtain and maintain high tissue levels of the drug at the site of vascular injury. To determine if local periadventitial delivery of dexamethasone decreases neointimal proliferation after balloon vascular injury, in three groups of Sprague-Dawley rats, 5% dexamethasone, 0.5% dexamethasone, and placebo silicone polymers were implanted around the left common carotid artery after balloon injury. In a fourth group, placebo polymers were implanted without balloon injury. Dexamethasone serum and tissue levels after polymer implantation were significantly higher in the 5% dexamethasone group compared with the 0.5% dexamethasone group. There was no neointima formation in any of the arterial segments covered with placebo polymers for 3 wk, but without balloon injury. In the arterial segments covered by the 5 and 0.5% dexamethasone polymers, there was a 76 and 75% reduction in intima/media ratios, respectively, compared with the placebo group (5% dexamethasone, 0.26 +/- 0.04; 0.5% dexamethasone, 0.27 +/- 0.03; placebo, 1.09 +/- 0.16, respectively; P < 0.0001). These results suggest that: (a) silicone polymers wrapped around the common carotid arteries for 3 wk did not, without balloon injury, stimulate neointimal proliferation in the rat model; (b) the activity of the drug-eluting polymer for suppressing intimal proliferation was chiefly, but not exclusively, site specific; and (c) transadventitial local delivery of dexamethasone at two different doses markedly inhibits neointimal proliferation after balloon vascular injury.This publication has 47 references indexed in Scilit:
- Direct intraarterial wall injection of microparticles via a catheter: A potential drug delivery strategy following angioplastyAmerican Heart Journal, 1991
- Arterial wall hypoxia following hyperfusion through the vasa vasorum is an initial lesion in atherosclerosisEuropean Journal of Clinical Investigation, 1990
- Effect of 18- to 24-hour heparin administration for prevention of restenosis after uncomplicated coronary angioplastyAmerican Heart Journal, 1989
- Local anticoagulation without systemic effect using a polymer heparin delivery system.Stroke, 1988
- Fos and jun: The AP-1 connectionCell, 1988
- Interleukin 1: a mitogen for human vascular smooth muscle cells that induces the release of growth-inhibitory prostanoids.Journal of Clinical Investigation, 1988
- Rationale for use of glucocorticoids in modification of restenosis after percutaneous transluminal coronary angioplastyThe American Journal of Cardiology, 1987
- Glucocorticoid influence on growth of vascular wall cells in cultureJournal of Cellular Physiology, 1982
- Effect of Cortisol on the Proliferation and Protein Synthesis of Human Aortic Smooth Muscle Cells in CultureActa Medica Scandinavica, 1982
- SUSTAINED RELEASE OF GENTAMICIN FROM PROSTHETIC HEART VALVESAsaio Journal, 1979