Quantitative magnetic resonance imaging of perfusion using magnetic labeling of water proton spins within the detection slice
- 1 April 1996
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 35 (4), 540-546
- https://doi.org/10.1002/mrm.1910350413
Abstract
A technique for noninvasive quantitative magnetic resonance imaging of perfusion is presented. It relies on using endogenous water as a freely diffusible tracer. Tissue water proton spins are magnetically labeled by slice-selective inversion, and longitudinal relaxation within the slice is detected using a fast gradient echo magnetic resonance imaging technique. Due to blood flow, nonexcited spins are washed into the slice resulting in an acceleration of the longitudinal relaxation process. Incorporating this phenomenon into the Bloch equation yields an expression that allows quantification of perfusion on the basis of a slice-selective and a nonselective inversion recovery experiment. Based on this technique, quantitative parameter maps of the regional cerebral blood flow (rCBF) were obtained from eight rats. Evaluation of regions of interest within the cerebral hemispheres yielded an average rCBF value of 104 ± 21 ml/min/100 g, which increased to 219 ± 30 ml/min/100 g during hypercapnia. The measured rCBF values are in good agreement with previously reported literature values.Keywords
This publication has 26 references indexed in Scilit:
- Magnetic resonance imaging of perfusion in the isolated rat heart using spin inversion of arterial waterMagnetic Resonance in Medicine, 1993
- Quantification of regional blood volumes by rapid T1 mappingMagnetic Resonance in Medicine, 1993
- Quantification of T1 values by SNAPSHOT-FLASH NMR imagingJournal of Magnetic Resonance (1969), 1992
- Perfusion imagingMagnetic Resonance in Medicine, 1992
- Proton NMR imaging of cerebral blood flow using H217OMagnetic Resonance in Medicine, 1991
- Suggested Reference Values for Regional Blood Volumes in HumansHealth Physics, 1991
- Cerebral blood flow measured by NMR indicator dilution in cats.Stroke, 1989
- A Highly Accurate Method of Localizing Regions of Neuronal Activation in the Human Brain with Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1989
- Concurrent measurements of cerebral blood flow, sodium, lactate, and high‐energy phosphate metabolism using 19F, 23Na, 1H, and 31P nuclear magnetic resonance spectroscopyMagnetic Resonance in Medicine, 1988
- Highly selective π2 and π pulse generationJournal of Magnetic Resonance (1969), 1984