MRI of Clot in Cerebral Venous Thrombosis

Abstract
Background and Purpose— In cerebral venous thrombosis (CVT), the sensitivity of conventional MRI sequences to detect clot in the sinuses or veins is incomplete and largely depends on the time elapsed since thrombus formation. Little is known concerning the corresponding diagnostic value of fluid-attenuated inversion recovery (FLAIR), echo-planar T2* susceptibility-weighted imaging (T2*SW) or diffusion-weighted images (DWI). Methods— We performed a retrospective analysis of 114 MRI examinations from 39 patients with CVT using a structured assessment. The time course of sensitivity in the detection of clot (n=166 clots) was analyzed for different MR sequences using a multilevel logistic model. The sensitivity of different MR sequences for diagnosis of cortical venous thrombosis was tested separately (n=38 clots). Results— The sensitivity of T2*SW and T1-weighted spin echo image (T1SE) sequences to detect clot in the sinuses or veins was estimated at 90% and 71% between day 1 and day 3, which was much higher...