Open-Tubular Capillary Electrochromatography with an On-Line Ion Trap Storage/Reflectron Time-of-Flight Mass Detector for Ultrafast Peptide Mixture Analysis
- 1 February 1997
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 69 (3), 320-326
- https://doi.org/10.1021/ac9609900
Abstract
In this work, a novel open-tubular column (OTC) capillary electrochromatography (CEC) system has been coupled to an on-line ion trap storage/reflectron time-of-flight mass spectrometer for ultrafast peptide mixture analysis. Reversed-phase OTCs prepared by the sol−gel process were coated with an amine, which greatly enhanced the electroosmotic flow in an acidic buffer solution and considerably reduced nonspecific adsorption between the peptides and the column wall. A six-peptide mixture could be separated to baseline within 3 min on this system. A full mass range detection speed of 8 Hz was used in all these experiments, which was sufficiently rapid to maintain the high efficiency of ultrafast separations. Because of the high duty cycle of the mass spectrometer and the column path length-independent concentration-sensitive feature of the electrospray ionization process, high-quality total ion chromatograms could be obtained with injections of only 1−2 fmol of peptide samples. A concentration limit of detection of 1 × 10-6 M was also achieved due to the preconcentration capability of CEC. In addition, a novel gradient CEC device was demonstrated which did not result in a pressure-driven flow. A tryptic digest of horse heart myoglobin was successfully separated on the gradient CEC system within 6 min. The use of the mass spectrometer increased the resolving power of this system by clearly identifying coeluting components.Keywords
This publication has 15 references indexed in Scilit:
- Protein Identification by Capillary Zone Electrophoresis/Microelectrospray Ionization-Tandem Mass Spectrometry at the Subfemtomole LevelAnalytical Chemistry, 1996
- Capillary Electrochromatography-Electrospray Mass Spectrometry: A Microanalysis TechniqueAnalytical Chemistry, 1995
- Pressurized gradient electro-high-performance liquid chromatographyJournal of Chromatography A, 1994
- Development of packed capillary column electrochromatography/mass spectrometryRapid Communications in Mass Spectrometry, 1994
- Pseudo-electrochromatography—negative-ion electrospray mass spectrometry of aromatic glucuronides and food coloursJournal of Chromatography A, 1993
- Electrokinetic reversed-phase chromatography with packed capillariesJournal of Chromatography A, 1992
- Chromatographic behavior in electrochromatographyAnalytical Chemistry, 1988
- Ion-selective electrodesAnalytical Chemistry, 1984
- High-resolution separations based on electrophoresis and electroosmosisJournal of Chromatography A, 1981
- Electro-osmosisJournal of Chromatography A, 1974