Sensitive, Specific Radioimmunoassay for Quantifying Pergolide in Plasma

Abstract
Pergolide, a synthetic ergoline with potent dopaminergic activity, is used to treat Parkinson disease. The low plasma concentrations of pergolide achieved during therapy complicate the development of a method for its analysis. Because radioimmunoassay successfully measures other structurally related ergolines in physiological fluids, we undertook the development of a radioimmunoassay of pergolide. The detection limit of the radioimmunoassay is 21 ng/L with an optimal working range from 100 to 1000 ng/L. We maximized assay specificity by using a monoclonal antibody that displayed low cross-reactivity with pergolide sulfoxide, a major metabolite found in animals. The radioimmunoassay has performed acceptably for > 2 years during toxicology studies with rats and rhesus monkeys and in clinical studies involving patients with Parkinson disease. We consider the radioimmunoassay a valid method for quantifying therapeutic concentrations of pergolide in plasma.