Abstract
A new graphical method for feedback control system compensation design yields the parameters of simple compensators which will place a closed-loop pole at a designated location in the 5-plane with arbitrary open-loop gain. The gain limits for compensators with single or multiple identical sections are easily determined by this method, which is simple, easy to apply, fast, and accurate. Examples are given to illustrate its utility.