The apparent diffusion constant measured by mri correlates with po2 in a rif‐1 tumor

Abstract
As tissue oxygen tension (pO2 is an important variable in cancer therapy, it would be of major clinical benefit to be able to measure pO2 noninvasively. Current methods for determining pO2 in clinical settings are limited to superficial tumors. The authors measured the apparent diffusion constant (ADC) in an implanted murine fibrosarcoma (RIF‐1) using magnetic resonance imaging and correlated the ADC with tissue pO2 measured by electron paramagnetic resonance oximetry. The ADC correlates significantly with tissue pO2 in this tumor (r = 0.89; n = 14) and so may provide a noninvasive index of pO2 in tumors.