Dose rate table for a 32P intravascular brachytherapy source from Monte Carlo calculations
- 9 August 2001
- journal article
- Published by Wiley in Medical Physics
- Vol. 28 (8), 1770-1775
- https://doi.org/10.1118/1.1384459
Abstract
Studies of intravascular brachytherapy to prevent restenosis following angioplasty have shown many promising results. Accurate dose rate tables based on detailed models of the brachytherapy sources are necessary for treatment planning. This work will present an away and along dose rate table for a 27 mm long catheter based 32P beta source. MD-55-2 radiochromic film has been exposed at five different depths (0.5 mm-4 mm) in a polystyrene phantom using a 27 mm long Guidant 32P beta source. The total dose to the active region of the film was determined using the absolute detector response of the MD-55-2 radiochromic film. The Monte Carlo code MCNP4B2 was also used to calculate the dose to the active region of the film using a detailed model of the source, encapsulation, and radiochromic film. The dose to film calculations showed good agreement with the measurements presented in this work with an average difference of 7%. The Monte Carlo calculations were also verified against previously published depth dose in water measurements determined using radiochromic film and plastic scintillator. The depth dose calculations in water showed good agreement with the previously published measurements with the calculations being about 2.5% lower than the film measurements and about 2.5% higher than the scintillator measurements. This work then uses the verified Monte Carlo code to present a dose rate table for the 32P intravascular beta source.Keywords
This publication has 9 references indexed in Scilit:
- Measurements and Monte Carlo calculations to determine the absolute detector response of radiochromic film for brachytherapy dosimetryMedical Physics, 2001
- β-Radiation to INHIBIT Recurrence of In-Stent Restenosis: Clinical and Angiographic Results of the Multicenter, Randomized, Double-Blind StudyCirculation, 2000
- Dosimetry characterization of 32P catheter-based vascular brachytherapy source wireMedical Physics, 2000
- Clinical experience with a spiral balloon centering catheter for the delivery of intracoronary radiation therapyCardiovascular Radiation Medicine, 1999
- Determination of a calibration factor for the nondestructive assay of Guidant 32P brachytherapy sourcesApplied Radiation and Isotopes, 1999
- Intravascular brachytherapy physics: Report of the AAPM Radiation Therapy Committee Task Group No. 60Medical Physics, 1999
- Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55Medical Physics, 1998
- Meta-analysis of randomised trials comparing coronary angioplasty with bypass surgeryThe Lancet, 1995
- Log-f tables for beta decayAtomic Data and Nuclear Data Tables, 1971