The Mechanical Behavior of Vascular Grafts: A Review
Top Cited Papers
Open Access
- 1 January 2001
- journal article
- review article
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 15 (3), 241-278
- https://doi.org/10.1106/na5t-j57a-jtdd-fd04
Abstract
The development of intimal hyperplasia (IH) near the anastomosis of a vascular graft to artery is directly related to changes in the wall shear rate distribution. Mismatch in compliance and diameter at the end-to-end anastomosis of a compliant artery and rigid graft cause shear rate disturbances that may induce intimal hyperplasia and ultimately graft failure. The principal strategy being developed to prevent IH is based on the design and fabrication of compliant synthetic or innovative tissue-engineered grafts with viscoelastic properties that mirror those of the human artery. The goal of this review is to discuss how mechanical properties including compliance mismatch, diameter mismatch, Young’s modulus and impedance phase angle affect graft failure due to intimal hyperplasia.Keywords
This publication has 137 references indexed in Scilit:
- Involvement of rho p21 in Cyclic Strain-Induced Tyrosine Phosphorylation of Focal Adhesion Kinase (pp125FAK), Morphological Changes and Migration of Endothelial CellsBiochemical and Biophysical Research Communications, 1996
- Early experience with stretch polytetrafluoroethylene grafts for haemodialysis access surgery: Results of a prospective randomised studyEuropean Journal of Vascular and Endovascular Surgery, 1995
- Glass Wool–H2O2/CoCl2 test system for in vitro evaluation of biodegradative stress cracking in polyurethane elastomersJournal of Biomedical Materials Research, 1995
- In vivo determination of human arterial compliance: Preliminary investigation of a new techniqueCardioVascular and Interventional Radiology, 1994
- The pathogenesis of atherosclerosis: a perspective for the 1990sNature, 1993
- Human plasma α2‐macroglobulin promotes in vitro oxidative stress cracking of pellethane 2363‐80A: In vivo and in vitro correlationsJournal of Biomedical Materials Research, 1993
- Effects of a vascular graft/natural artery compliance mismatch on pulsatile flowJournal of Biomechanics, 1992
- Numerical Analysis of Flow in an Elastic Artery ModelJournal of Biomechanical Engineering, 1992
- Compliance Effect on Patency of Small Diameter Vascular GraftsAnnual Northeast Bioengineering Conference, 1989
- Biomechanics: Mechanical Properties of Living TissuesJournal of Biomechanical Engineering, 1981