Shear-induced unfolding triggers adhesion of von Willebrand factor fibers
Top Cited Papers
- 8 May 2007
- journal article
- Published by Proceedings of the National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 104 (19), 7899-7903
- https://doi.org/10.1073/pnas.0608422104
Abstract
Von Willebrand factor (VWF), a protein present in our circulatory system, is necessary to stop bleeding under high shear-stress conditions as found in small blood vessels. The results presented here help unravel how an increase in hydrodynamic shear stress activates VWF's adhesion potential, leading to the counterintuitive phenomena of enhanced adsorption rate under strong shear conditions. Using a microfluidic device, we were able to mimic a wide range of bloodflow conditions and directly visualize the conformational dynamics of this protein under shear flow. In particular, we find that VWF displays a reversible globule-stretch transition at a critical shear rate gamma(crit) in the absence of any adsorbing surface. Computer simulations reproduce this sharp transition and identify the large size of VWF's repeating units as one of the keys for this unique hydrodynamic activation. In the presence of an adsorbing collagen substrate, we find a large increase in the protein adsorption at the same critical shear rate, suggesting that the globule unfolding in bulk triggers the surface adsorption in the case of a collagen substrate, which provides a sufficient density of binding sites. Monitoring the adsorption process of multiple VWF fibers, we were able to follow the formation of an immobilized network that constitutes a "sticky" grid necessary for blood platelet adhesion under high shear flow. Because areas of high shear stress coincide with a higher chance for vessel wall damage by mechanical forces, we identified the shear-induced increase in the binding probability of VWF as an effective self-regulating repair mechanism of our microvascular system.Keywords
This publication has 24 references indexed in Scilit:
- Shear-Flow-Induced Unfolding of Polymeric GlobulesPhysical Review Letters, 2006
- Size regulation of von Willebrand factor–mediated platelet thrombi by ADAMTS13 in flowing bloodBlood, 2006
- Cleavage of ultra‐large von Willebrand factor by ADAMTS‐13 under flow conditionsJournal of Thrombosis and Haemostasis, 2005
- Orientation of elastic rods in homogeneous Stokes flowEurophysics Letters, 2005
- The von Willebrand factor self-association is modulated by a multiple domain interactionJournal of Thrombosis and Haemostasis, 2005
- Flow profiling of a surface-acoustic-wave nanopumpPhysical Review E, 2004
- Weakly adhering vesicles in shear flow: Tanktreading and anomalous lift forceEurophysics Letters, 2000
- Hydrodynamic Lift on Bound VesiclesPhysical Review Letters, 1999
- Unwinding of Globular Polymers under Strong FlowsMacromolecules, 1996
- Involvement of large plasma von Willebrand factor (vWF) multimers and unusually large vWF forms derived from endothelial cells in shear stress-induced platelet aggregation.Journal of Clinical Investigation, 1986