An alternative method for smear preparation of fine-needle aspiration cytology of cystic thyroid lesions: Evaluation of sample adequacy
- 1 November 2020
- journal article
- research article
- Published by Wiley in Diagnostic Cytopathology
- Vol. 48 (11), 1054-1057
- https://doi.org/10.1002/dc.24525
Abstract
Background Cystic thyroid lesions represent one of the most common causes of unsatisfactory fine-needle aspiration sampling. Thus, it is important to access the maximum number of follicular cells from cystic fluid in order to reduce unsatisfactory rates. We compared the traditional method of smearing with an alternative one. Methods For each thyroid nodule, two smears were collected. Each smear was prepared using a distinct approach: either using the traditional technique or the alternative. Clinical data were taken from cytopathological request forms. The cytological aspects of the smears (eg, adequacy and number of cells) were observed during microscopy analysis. No cases were found to be suspicious for malignancy during ultrasound analysis (categories TR1 or TR2 according to ACR TI-RADS). Results Thirty-five cases were analyzed. For smears prepared using both the traditional and the alternative techniques, 20 and 4 cases, respectively, were unsatisfactory. In the 20 unsatisfactory traditional smear cases, 9 (45%) showed enough cells for diagnosis in cytospin and/or cell block samples; the four unsatisfactory alternative method cases showed the same. There was a statistical difference between the two methods of collecting a smear concerning sample adequacy (P< .001), but there was no statistical difference regarding the cellularity (P= .842). Conclusion In our data, the alternative method of using only one slide and the needle tip had higher rates of adequate sampling. Since it is cost effective and does not change the cytological analysis, this proposed alternative method can be useful in cases of cystic thyroid lesions.Keywords
This publication has 13 references indexed in Scilit:
- The Bethesda System for Reporting Thyroid CytopathologyPublished by Springer Nature ,2018
- ACR Thyroid Imaging, Reporting and Data System (TI-RADS): White Paper of the ACR TI-RADS CommitteeJournal of the American College of Radiology, 2017
- Reappraisal of “cyst fluid only” on thyroid fine-needle aspiration cytologyEndocrine Journal, 2017
- Factors Influencing the Reliability of Thyroid Fine-Needle Aspiration: Analysis of Thyroid Nodule Size, Guidance Mode for Aspiration and Preparation MethodActa Cytologica, 2015
- Atlas of Fine Needle Aspiration CytologyPublished by Springer Nature ,2014
- Fine-Needle Biopsy of Superficial and Deep MassesPublished by Springer Nature ,2009
- The Impact of Assessing Specimen Adequacy and Number of Needle Passes for Fine-Needle Aspiration Biopsy of Thyroid NodulesThyroid®, 2006
- Comparative Study of Fine Needle Aspiration and Fine Needle Capillary Sampling of Thyroid LesionsActa Cytologica, 2002
- Nondiagnostic Fine Needle Aspiration Biopsy of the Thyroid GlandActa Cytologica, 1996
- Smearing techniques for the concentration of particles from fine needle aspiration biopsyDiagnostic Cytopathology, 1985