Microfluidic-Based DNA Purification in a Two-Stage, Dual-Phase Microchip Containing a Reversed-Phase and a Photopolymerized Monolith
- 11 July 2007
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (16), 6135-6142
- https://doi.org/10.1021/ac0703698
Abstract
In this report, we show that a novel capillary-based photopolymerized monolith offering unprecedented efficiency (∼80%) for DNA extraction from submicroliter volumes of whole blood (Wen, J.; Guillo, C.; Ferrance, J. P.; Landers, J. P. Anal. Chem.2006, 78, 1673−1681) can be translated to microfluidic devices. However, owing to the large mass of protein present in blood, both DNA binding capacity and extraction efficiency were significantly decreased when extraction of DNA was carried out directly from whole blood (38 ± 1%). To circumvent this, a novel two-stage microdevice was developed, consisting in a C18 reversed-phase column for protein capture (stage 1) in series with a monolithic column for DNA extraction (stage 2). The two-stage, dual-phase design improves the capability of the monolith for whole blood DNA extraction by ∼100-fold. From a 10-μL load of whole blood containing 350 ng of DNA, 99% (340 ± 10 ng) traverses the C18 phase while ∼70% (1020 ± 45 ug) of protein is retained. A total of 240 ± 2 ng of DNA was eluted from the second-stage monolith, resulting in an overall extraction efficiency of 69 ± 1%. This provided not only an improvement in extraction efficiency over other chip-based DNA extraction solid phases but also the highest extraction efficiency reported to-date for such sample volumes in a microfluidic device. As an added bonus, the two-stage, dual-phase microdevice allowed the 2-propanol wash step, typically required to remove proteins from the DNA extraction phase for successful PCR, to be completely eliminated, thus streamlining the process without affecting the PCR amplifiability of the extracted DNA.Keywords
This publication has 17 references indexed in Scilit:
- A fully integrated microfluidic genetic analysis system with sample-in–answer-out capabilityProceedings of the National Academy of Sciences, 2006
- Purification and preconcentration of genomic DNA from whole cell lysates using photoactivated polycarbonate (PPC) microfluidic chipsNucleic Acids Research, 2006
- Microchip‐Based Cell Lysis and DNA Extraction from Sperm Cells for Application to Forensic AnalysisJournal of Forensic Sciences, 2006
- A Simple, Valveless Microfluidic Sample Preparation Device for Extraction and Amplification of DNA from Nanoliter-Volume SamplesAnalytical Chemistry, 2006
- Fabrication of amino silane-coated microchip for DNA extraction from whole bloodJournal of Biotechnology, 2005
- Toward sol-gel electrochromatographic separations on a chipJournal of Separation Science, 2002
- Epigenetic Regulation of Gelsolin Expression in Human Breast Cancer CellsExperimental Cell Research, 1999
- Guanidine Hydrochloride-induced Folding of ProteinsJournal of Molecular Biology, 1993
- Continuous rods of macroporous polymer as high-performance liquid chromatography separation mediaAnalytical Chemistry, 1992
- Rapid signal processing techniques for Fourier transform infrared remote sensingTrAC Trends in Analytical Chemistry, 1991