Auditory Frequency Selectivity in Normal and Presbycusic Subjects

Abstract
Auditory frequency selectivity was inferred from measurements of the detectability of tonal signals as a function of the cutoff frequency of a low-pass computer-generated noise masker. In Experiment I the effect of small changes in signal-to-noise ratio on inferred auditory frequency selectivity was studied. In Experiment II, frequency selectivity was determined for five normal-hearing subjects and four subjects with sensorineural hearing loss due to presbycusis. Critical ratios (signal-to-noise ratio at masked threshold) also were determined in Experiment II. The results of Experiment I indicate that the low-pass masking experiment provides a stable estimate of the width, but not the position, of the critical masking band. Experiment II revealed elevated critical ratios for three of the four presbycusic subjects. Some hearing-impaired subjects appeared to have normal frequency selectivity despite elevated critical ratios. Other presbycusic subjects demonstrated impaired auditory frequency selectivity. The results suggest that critical ratio and critical masking band data are free to vary independently in hearing-impaired subjects.