Localized osteolysis in stable, non-septic total hip replacement.
- 1 July 1986
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 68 (6), 912-919
- https://doi.org/10.2106/00004623-198668060-00014
Abstract
We are reporting four cases of extensive, localized bone resorption adjacent to a rigidly anchored, cemented total hip replacement. None of these hips showed evidence of infection on clinical, bacteriological, or pathological evaluation. The tissue from the regions of osteolysis showed sheets of macrophages and foreign-body giant cells invading the femoral cortices. Abundant methylmethacrylate particulate debris was present in the tissues, but polyethylene wear debris was absent. The histological appearance of this tissue resembled that reported about loosened total hip implants with the exception of the synovial-like layer at the cement surface. The cases reported here show that aggressive bone lysis may occur around stable cemented total hip arthroplasties without the presence of sepsis or malignant disease.This publication has 5 references indexed in Scilit:
- The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis.Journal of Bone and Joint Surgery, 1983
- Localized Bone Resorption in the Femur in Mechanical Failure of Cemented Total Hip ArthroplastiesActa Orthopaedica, 1983
- Cells of the mononuclear phagocytic system resorb implanted bone matrix: A histologic and ultrastructural studyCalcified Tissue International, 1982
- Histologische untersuchungen über umbauvorgänge an der zement-knochengrenze bei endoprothesen nach 3-bis 10-jähriger implantationPathology - Research and Practice, 1982
- Direct Resorption of Bone by Human MonocytesScience, 1977