Corneal changes after cataract surgery with 5.0 mm sutured and 3.5 mm sutureless clear corneal incisions
- 1 April 1997
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 23 (3), 342-346
- https://doi.org/10.1016/s0886-3350(97)80177-0
Abstract
To study corneal changes after endocapsular phacoemulsification cataract extraction and intraocular lens (IOL) implantation with a 3.5 mm clear corneal sutureless incision or a 5.0 mm clear corneal incision with an absorbable suture. Northwest Kansas Eye Clinic, Hays, Kansas, USA. In a prospective study, 200 eyes were randomly distributed into two groups. Group A comprised 100 eyes that had a silicone IOL inserted through a 3.5 mm sutureless clear corneal incision. Group B comprised 100 eyes that had a 5.0 mm poly(methyl methacrylate) (PMMA) IOL inserted through a 5.0 mm clear corneal incision; one half of the closures used a single radial suture (Group B1), and the other half, an X suture (Group B2). Preoperatively, corneal topography and corneal endothelial cell counts were performed. Six to 8 months postoperatively, they were repeated and evaluated. Differential topography was used to determine the difference between the preoperative and postoperative corneas. During the final postoperative visit, IOL centration was evaluated. All closures produced only minimal changes in the corneal topographic indices. The postoperative corneas closely resembled the preoperative corneas. Polar K values showed a slight astigmatic shift in all groups. Group B2 was the only one to exhibit a with-the-rule shift. The change in endothelial cell counts was minimal and comparable in all three groups. The small amount of change in the corneal indices, especially in surface regularity, indicates that all corneas were relatively comparable and stable 6 to 9 months postoperatively regardless of the type of incision and closure method.Keywords
This publication has 12 references indexed in Scilit:
- The Correlation between Incision Size and Corneal Shape Changes in Sutureless Cataract SurgeryOphthalmology, 1995
- Astigmatic decay following small incision, self-sealing cataract surgeryJournal of Cataract & Refractive Surgery, 1994
- Effect of incision size on early postoperative visual rehabilitation after cataract surgery and intraocular lens implantationJournal of Cataract & Refractive Surgery, 1993
- Astigmatism after Small Incision Cataract SurgeryOphthalmology, 1991
- Quantitative Descriptors of Corneal TopographyArchives of Ophthalmology (1950), 1991
- Comparison of postoperative astigmatism with incisions of varying length closed with horizontal sutures and with no suturesJournal of Cataract & Refractive Surgery, 1991
- Keratometric cylinder and visual recovery following phacoemulsification and intraocular lens implantation using a self-sealing cataract incisionJournal of Cataract & Refractive Surgery, 1991
- Early results of 500 cases of no-stitch cataract surgeryJournal of Cataract & Refractive Surgery, 1991
- Induced astigmatism in small incision cataract surgeryJournal of Cataract & Refractive Surgery, 1989
- Small incisions to control astigmatism during cataract surgeryJournal of Cataract & Refractive Surgery, 1989