Validity of Transdermal Alcohol Monitoring: Fixed and Self‐Regulated Dosing
- 6 January 2006
- journal article
- research article
- Published by Wiley in Alcohol, Clinical and Experimental Research
- Vol. 30 (1), 26-33
- https://doi.org/10.1111/j.1530-0277.2006.00004.x
Abstract
Background: To study the validity of transdermal assessment of alcohol concentration measured by a lightweight, noninvasive device. Methods: Subjects wore a 227‐g anklet that sensed transdermal alcohol concentrations (TACs) every 15 to 30 minutes, downloading results to a remote computer each day. Twenty‐four subjects entered a laboratory and received a dose of 0, 0.28, or 0.56 g/kg of ethanol. Breath alcohol concentrations (BrAC) and TAC were measured every 15 to 30 minutes Twenty others [10 alcohol dependent (AD) and 10 not (NAD)] in the community who wore the anklet for 8 days kept a drinking log and provided a BrAC sample each day. Results: In the laboratory, no zero‐dose subject, and every subject receiving alcohol, had alcohol‐positive TACs. The device distinguished low‐ and high‐alcohol–dosing groups using peak (t14=3.37; pt14=3.42; pt18=−3.77; pt9.5=−3.56; pt9.9=−3.35; p<0.01) all significantly distinguished the AD and NAD groups. However, individual transdermal readings were not reliably quantitatively equivalent to simultaneously obtained breath results. Conclusions: Within the limits of the laboratory study, the device consistently detected consumption of approximately 2 standard drinks. On average, the device shows discriminative validity as a semiquantitative measure of alcohol consumption but individual readings often are not equivalent to simultaneous BrACs.Keywords
This publication has 20 references indexed in Scilit:
- Factors associated with methadone maintenance treatment retention among street-recruited injection drug usersDrug and Alcohol Dependence, 2004
- Transdermal Alcohol Measurement for Estimation of Blood Alcohol ConcentrationAlcohol, Clinical and Experimental Research, 2000
- The use of the DSM-III-R Checklist for initial diagnostic assessmentsComprehensive Psychiatry, 1993
- Studies on a Wearable, Electronic, Transdermal Alcohol SensorAlcohol, Clinical and Experimental Research, 1992
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Subjective Responses to the Sweat-Patch Test for Alcohol ConsumptionAdvances in Alcohol & Substance Abuse, 1984
- Accuracy and usefulness of a breath alcohol analyzerAnnals of Emergency Medicine, 1984
- Sweat‐Patch Testing Detects Inaccurate Self‐Reports of Alcohol ConsumptionAlcohol, Clinical and Experimental Research, 1984
- A comparison of numerical integrating algorithms by trapezoidal, Lagrange, and spline approximationJournal of Pharmacokinetics and Biopharmaceutics, 1978
- Pharmacokinetics of ethanol after oral administration in the fasting stateJournal of Pharmacokinetics and Biopharmaceutics, 1977