Radiation protection standards: their evolution from science to philosophy
- 20 December 2005
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 115 (1-4), 16-22
- https://doi.org/10.1093/rpd/nci133
Abstract
The concept of applying constraints on individual sources to a small fraction of the public dose limit has been deemed inappropriate when shielding the medical X-ray sources. This represents a broad-based consensus of medical physics and radiological societies in the United States, and the report series on the shielding design for medical X-ray sources (including dental, X-ray imaging and therapeutic X ray) from the National Council on Radiation Protection and Measurements (NCRP) utilises 1 mSv y−1 as a source control limit. In the present study, the rationale for such a conclusion is discussed, and a somewhat critical look at the current model of radiation protection of the public is made.Keywords
This publication has 6 references indexed in Scilit:
- Secondary Shielding Barriers for Diagnostic X-Ray FacilitiesHealth Physics, 1998
- Primary Shielding Barriers for Diagnostic X-Ray FacilitiesHealth Physics, 1998
- Radiation shielding for spiral CT scanners.The British Journal of Radiology, 1997
- Five‐Hundred Life‐Saving Interventions and Their Cost‐EffectivenessRisk Analysis, 1995
- On the primary barrier in diagnostic x‐ray shieldingMedical Physics, 1994
- Quantities used in radiological protectionAnnals of the ICRP, 1991