Volume-Rendered Multidetector CT Angiography: Noninvasive Follow-Up of Patients Treated with Renal Artery Stents
- 1 January 2003
- journal article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 180 (1), 233-239
- https://doi.org/10.2214/ajr.180.1.1800233
Abstract
OBJECTIVE. The purpose of our study was to evaluate the role of multidetector CT (MDCT) angiography with volume rendering for estimating the patency of renal artery stents. SUBJECTS AND METHODS. In 16 patients, 16 renal artery stents were evaluated with MDCT renal angiography and digital subtraction angiography (DSA). CT data were evaluated using multiplanar volume reformations and the volume-rendering algorithm with three different volume-rendered parameter settings (low-to-high, high-to-low, and high—low—high opacity transfer functions: VRLH, VRHL, and VRVE, respectively). Targeted images of each stent were rendered in paraaxial and paracoronal planes and were interactively interpreted. The overall restenosis severity was measured on postprocessed paraaxial and paracoronal images and compared with that obtained on DSA using linear regression analysis. Image quality and lumen delineation on rendered images were also compared using Wilcoxon's signed rank test. RESULTS. Eight restenoses were identified on DSA. Correlations between restenosis severity measured with DSA and those measured with MDCT were significant (p < 0.001). Volume rendering with VRHL allowed the best correlation with DSA (reviewer 1, r2 = 0.86; reviewer 2, r2 = 0.94) and was significantly better than multiplanar volume reformations (p = 0.028). Overall image quality was high with all rendering techniques and with no significant differences (p > 0.59, for all comparisons). Stent lumen was well delineated with volume-rendering modalities; however, VRHL was significantly better than VRLH (p = 0.033). CONCLUSION. Volume-rendered MDCT angiography enabled high-quality three-dimensional reproducible evaluation of the patency of implanted renal artery stents. Volume rendering with VRHL achieved the best performance.Keywords
This publication has 19 references indexed in Scilit:
- Thin-Section Multidetector CT Angiography of Renal Artery StentsAmerican Journal of Roentgenology, 2002
- CT AngiographyAmerican Journal of Roentgenology, 2001
- Stent Placement for Renal Arterial Stenosis: Where Do We Stand? A Meta-analysisRadiology, 2000
- Aorta and Iliac Arteries: Single versus Multiple Detector-Row Helical CT AngiographyRadiology, 2000
- Duplex ultrasonography in assessing restenosis of renal artery stentsCardioVascular and Interventional Radiology, 1999
- CT angiography with volume rendering for quantifying vascular stenoses: in vitro validation of accuracy.American Journal of Roentgenology, 1999
- Plain and Covered Stent-Grafts: In Vitro Evaluation of Characteristics at Three-dimensional MR AngiographyRadiology, 1999
- Renal Artery Stenosis: CT Angiography—Comparison of Real-time Volume-rendering and Maximum Intensity Projection AlgorithmsRadiology, 1999
- Dynamic Gadolinium DTPA-Enhanced Magnetic Resonance of Intravascular StentsInvestigative Radiology, 1998
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986