Static and dynamic analysis of the anterior segment with optical coherence tomography
- 1 September 2004
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 30 (9), 1843-1850
- https://doi.org/10.1016/j.jcrs.2004.05.024
Abstract
To study biometric modifications of the anterior segment with accommodation and age and determine possible applications in areas of anterior segment surgery, particularly implantation of refractive lenses. Clinique Monticelli, Marseille, France. The study comprised subjects between 7 years of age and 82 years of age in whom anterior chamber biometry was evaluated using 1310 nm wavelength optical coherence tomography (OCT). The equipment has a fixation target that can be focused and defocused with negative lenses to stimulate natural accommodation. All measurements were performed by the same operator. The horizontal diameter of the AC, the anterior chamber depth (ACD), the horizontal pupil diameter, and the horizontal radius of curvature of the crystalline lens' anterior pole were measured in the unaccommodated state and after stimulating accommodation. Fifty-six subjects (104 eyes) were included; the refractions ranged from +5.0 diopters (D) to −5.0 D. The static and dynamic measurements were compared with ametropia, age, and accommodation. At rest, the mean AC diameter was 12.334 mm, the mean ACD was 3.106 mm, and the mean pupil diameter was 4.258 mm. With 1.0 D of accommodation, the anterior pole moved forward by a mean of 30 μm, the radius of curvature decreased 0.3 mm, and the pupil diameter decreased 0.15 mm. The AC OCT is a user-friendly instrument for evaluating the anterior segment and examining the AC (cornea, iris, crystalline lens, and iridocorneal angle). The 1310 nm light wavelength is blocked by pigments, preventing examination behind the iris. However, the AC OCT is capable of good image quality and visualization of the anatomical relationships in the anterior segment, even behind an opaque cornea.Keywords
This publication has 12 references indexed in Scilit:
- Contact between 3 phakic intraocular lens models and the crystalline lens: An anterior chamber optical coherence tomography studyJournal of Cataract & Refractive Surgery, 2004
- Anterior chamber optical coherence tomography study of human natural accommodation in a 19-year-old albinoJournal of Cataract & Refractive Surgery, 2004
- Aging of the human lens: changes in lens shape upon accommodation and with accommodative lossJournal of the Optical Society of America A, 2002
- Real-Time Optical Coherence Tomography of the Anterior Segment at 1310 nmArchives of Ophthalmology (1950), 2001
- Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence TomographyArchives of Ophthalmology (1950), 1994
- Aging of the human crystalline lens and anterior segmentVision Research, 1994
- Optical Coherence TomographyScience, 1991
- Slit-lamp studies of the rhesus monkey eye: H. changes in crystalline lens shape, thickness and position during accommodation and agingExperimental Eye Research, 1987
- Analysis of human crystalline lens curvature as a function of accommodative state and ageVision Research, 1984
- Ueber die Accommodation des AugesAlbrecht von Graefes Archiv für Ophthalmologie, 1855