Deformable registration of abdominal kilovoltage treatment planning CT and tomotherapy daily megavoltage CT for treatment adaptation
- 7 January 2009
- journal article
- Published by Wiley in Medical Physics
- Vol. 36 (2), 329-338
- https://doi.org/10.1118/1.3049594
Abstract
In adaptive radiation therapy the treatment planning kilovoltage CT (kVCT) images need to be registered with daily CT images. Daily megavoltage CT (MVCT) images are generally noisier than the kVCT images. In addition, in the abdomen, low image contrast, differences in bladder filling, differences in bowel, and rectum filling degrade image usefulness and make deformable image registration very difficult. The authors have developed a procedure to overcome these difficulties for better deformable registration between the abdominal kVCT and MVCT images. The procedure includes multiple image preprocessing steps and a two deformable registration steps. The image preprocessing steps include MVCT noise reduction, bowel gas pockets detection and painting, contrast enhancement, and intensity manipulation for critical organs. The first registration step is carried out in the local region of the critical organs (bladder, prostate, and rectum). It requires structure contours of these critical organs on both kVCT and MVCT to obtain good registration accuracy on these critical organs. The second registration step uses the first step results and registers the entire image with less intensive computational requirement. The two-step approach improves the overall computation speed and works together with these image preprocessing steps to achieve better registration accuracy than a regular single step registration. The authors evaluated the procedure on multiple image datasets from prostate cancer patients and gynecological cancer patients. Compared to rigid alignment, the proposed method improves volume matching by over 60% for the critical organs and reduces the prostate landmark registration errors by 50%.Keywords
This publication has 23 references indexed in Scilit:
- A fast inverse consistent deformable image registration method based on symmetric optical flow computationPhysics in Medicine & Biology, 2008
- Deformable registration of the planning image (kVCT) and the daily images (MVCT) for adaptive radiation therapyPhysics in Medicine & Biology, 2006
- Large deformation three-dimensional image registration in image-guided radiation therapyPhysics in Medicine & Biology, 2005
- The use of megavoltage CT (MVCT) images for dose recomputationsPhysics in Medicine & Biology, 2005
- Statistical validation of brain tumor shape approximation via spherical harmonics for image-guided neurosurgeryAcademic Radiology, 2005
- Automated model-based organ delineation for radiotherapy planning in prostatic regionInternational Journal of Radiation Oncology*Biology*Physics, 2004
- Adaptive radiation therapyPhysics in Medicine & Biology, 1997
- The Laplacian Pyramid as a Compact Image CodeIEEE Transactions on Communications, 1983
- Determining optical flowArtificial Intelligence, 1981
- Measures of the Amount of Ecologic Association Between SpeciesEcology, 1945