Echocardiographic Characteristics of Premature Infants with Patent Ductus Arteriosus
- 1 December 1983
- journal article
- research article
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 72 (6), 864-871
- https://doi.org/10.1542/peds.72.6.864
Abstract
As part of a multicenter collaborative study, M-mode echocardiograms were obtained shortly after birth on 3,559 premature infants with birth weight ≤1,750 g. Of these infants, 1,496 did not develop a cardiac murmur or other signs of a "hemodynamically significant" patent ductus arteriosus (PDA). Echocardiographic parameters from this "normal" group were compared with results obtained from 415 infants in whom PDA was diagnosed on the basis of clinical findings alone, irrespective of the echocardiogram (PDA group). The best discrimination between the two groups, when considering a single parameter, was provided by a left atrial to aortic root ratio (LA/AO) of 1.40, a left ventricular to aortic root ratio (LV/AO) of 2.10, or a left ventricular systolic time interval ratio (LPEP/LVET) of 0.27. Multivariate analysis demonstrated that better separation between the two groups occurred when the left atrial to aortic root ratio and the left ventricular systolic time interval ratio were considered jointly. Because of a large degree of overlap of all echocardiographic variables between the normal group and the group with PDA, the echocardiogram alone was not a good indicator of PDA. However, when used in conjunction with a priori estimates of the probability of PDA (based, for example, on birth weight and degree of respiratory disease), use of echocardiographic data was found to improve the detection of hemodynamically significant patent ductus arteriosus in premature infants.Keywords
This publication has 13 references indexed in Scilit:
- Patent ductus arteriosus treated with ligation orindomethacin: A follow-up studyThe Journal of Pediatrics, 1979
- Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.Circulation, 1978
- Effects of recording speed on precision of time-based polycardiographic measurements. Optimal paper speeds for measuring points and intervals.Heart, 1978
- Closure of the patent ductus arteriosus with ligation and indomethacin: A consecutive experienceThe Journal of Pediatrics, 1978
- Echocardiographic diagnosis: Pitfalls in the premature infant with a large patent ductus arteriosusThe Journal of Pediatrics, 1978
- Patent Ductus Arteriosus in Preterm Infants with Idiopathic Respiratory Distress SyndromeRadiology, 1977
- Left ventricular performance in the critically ill premature infant with patent ductus arteriosus and pulmonary disease.Circulation, 1977
- Closure of the Ductus Arteriosus in Premature Infants by Inhibition of Prostaglandin SynthesisNew England Journal of Medicine, 1976
- Pharmacologic Closure of Patent Ductus Arteriosus in the Premature InfantNew England Journal of Medicine, 1976
- Delayed closure of the ductus arteriosusThe Journal of Pediatrics, 1966