Titanium‐coated micromachined grooves of different dimensions affect epithelial and connective‐tissue cells differently in vivo
- 13 September 1990
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 24 (9), 1203-1219
- https://doi.org/10.1002/jbm.820240906
Abstract
A desirable feature of an implant surface which penetrates epithelium would be that the surface impedes epithelial downgrowth. Previous experiments have shown that the micromachined, horizontally oriented grooves on the percutaneous implant surface can impede epithelial downgrowth (Chehroudi et al., J. Biomed. Mater. Res., 22, 459 (1988) and 23, 1067 (1989)). However, little is known of the effect of varying groove parameters such as depth, spacing, and orientation on epithelial downgrowth and attachment of epithelial (E)‐cells and fibroblasts (F) to percutaneous implants in vivo. Grooves were produced with a 30‐μm pitch and depths of 22 μm, 10 μm, or 3 μm. In addition, 10‐μm‐ and 3‐μm‐deep grooves were made with pitches of 39 μm and 7 μm, respectively. Implants with grooves oriented either horizontally or vertically to the long axis of the implant as well as smooth control surfaces were coated with 50 nm of titanium and placed in the parietal area of rats for a period of 7 days. Close attachment of E‐cells was found on the smooth, 10‐μm‐ and 3‐μm‐deep, horizontally or vertically aligned grooved surfaces; in contrast, E‐cells bridged over the 22‐μm‐deep, horizontally oriented grooves. F formed a capsule on the smooth surface as well as the 10‐μm‐ and 3‐μm‐deep horizontally oriented grooves, but F inserted obliquely into the 22‐μm‐deep, horizontally aligned grooved surface. Histomorphometric measurements indicated that the epithelial downgrowth was greatest on the vertically oriented grooved and smooth surfaces and was shortest on the 22‐μm‐deep and 10‐μm‐deep horizontally aligned grooved surfaces. These differences indicate that epithelial downgrowth was accelerated on the vertically oriented grooved surfaces and inhibited on the horizontally oriented grooved surfaces. Moreover, the mechanism of inhibition of the epithelial downgrowth may differ among these surfaces. E‐cells bridged over the 22‐μm‐deep grooves and their migration appeared to be inhibited by the F that inserted into the implant surface. In the shallower horizontal grooves, however, epithelial downgrowth was probably inhibited by contact guidance because there was no evidence of F inserting obliquely into the implant surface.This publication has 20 references indexed in Scilit:
- Effects of a grooved epoxy substratum on epithelial cell behavior in vitro and in vivoJournal of Biomedical Materials Research, 1988
- Guinea pig and rabbit model for the histological evaluation of permanent percutaneous implantsBiomaterials, 1988
- Effect of the surface geometry of smooth and porous‐coated titanium alloy on the orientation of fibroblasts in vitroJournal of Biomedical Materials Research, 1987
- Spreading and orientation of epithelial cells on grooved substrataExperimental Cell Research, 1986
- Fibroblasts on micromachined substrata orient hierarchically to grooves of different dimensionsExperimental Cell Research, 1986
- Applications and failure modes of percutaneous devices: A reviewJournal of Biomedical Materials Research, 1984
- The relationship between soft tissue attachment, epithelial downgrowth and surface porosityJournal of Periodontal Research, 1981
- Histopathology of Oral Endosteal Metallic Implants in DogsJournal of Dental Research, 1973
- Cellular DynamicsReviews of Modern Physics, 1959