Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control
Top Cited Papers
Open Access
- 19 September 2006
- journal article
- cardiac
- Published by Springer Nature in European Radiology
- Vol. 16 (12), 2739-2747
- https://doi.org/10.1007/s00330-006-0474-0
Abstract
The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1±11.3 years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14±9 days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter ≥1.5 mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3±3.9 kg/m2 (range 22.4–36.3 kg/m2), mean heart rate during CT was 70.3±14.2 bpm (range 47–102 bpm), and mean Agatston score was 821±904 (range 0–3,110). Image quality was diagnostic (scores 1–3) in 98.6% (414/420) of segments (mean image quality score 1.68±0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control.Keywords
This publication has 30 references indexed in Scilit:
- Accuracy of 64-MDCT in the Diagnosis of Ischemic Heart DiseaseAmerican Journal of Roentgenology, 2006
- Coronary artery imaging with 64-slice computed tomography from cardiac surgical perspective?European Journal of Cardio-Thoracic Surgery, 2006
- Multislice CT Coronary Angiography: Effect of Sublingual Nitroglycerine on the Diameter of Coronary ArteriesRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2006
- Image Quality, Motion Artifacts, and Reconstruction Timing of 64-Slice Coronary Computed Tomography Angiography With 0.33-Second Rotation SpeedInvestigative Radiology, 2006
- Usefulness of Multidetector Row Spiral Computed Tomography With 64- × 0.6-mm Collimation and 330-ms Rotation for the Noninvasive Detection of Significant Coronary Artery StenosesThe American Journal of Cardiology, 2005
- Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed TomographyJournal of the American College of Cardiology, 2005
- Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed TomographyJournal of the American College of Cardiology, 2005
- Impact of Coronary Calcium Score on Diagnostic Accuracy for the detection of Significant Coronary Stenosis With Multislice Computed Tomography AngiographyThe American Journal of Cardiology, 2005
- Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology: Initial clinical resultsJournal of the American College of Cardiology, 2004
- A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart AssociationCirculation, 1975