Abstract
Allen Video-enhanced constrast/differential interference constrast (AVEC-DIC) microscopy was used in conjunction with video intensification immunofluorescence microscopy to demonstrate that organelles and vesicle (particles) can move in either direction along microtubular linear elements in fibroblasts [Hayden et al., 1983]. Since it is not possible to determine the number of microtubules making up a linear element with light microscopy alone, AVEC-DIC microscopy was used in conjunction with whole-mount electron microscopy to show bidirectional transport along a single microtubule [Hayden and Allen, 1984]. These studies demonstrate that the structural polarity of the microtubule does not determine the direction of particle motion, and since dynein is an asymetric molecule, a simple microtubule-dynein-particle hypothesis cannot explain bidirectional transport along a single microtubule. Very little is known about regulation of particle transport in most cell types. Human embryonic lung fibroblasts grown on glass coverslips were serum-deprived for 24 hours and re-fed with serumless medium; the particle translocations/5 minutes were then determined The cells were then re-fed with either serumless medium, serum-containing medium, or serumless medium containing some bioactive factor, and the particle translocations/5 minutes were again determined for the same cells. Medium containing 10% fetal bovine serum inhibited particle translocation by 51.8%. Of the bioactive factors tested, only vasopressin produced a significant reduction in particle translocations (38%). This suggests that protein kinase C or calcium/calmodulin kinase could be involved in regulating particle transport.

This publication has 24 references indexed in Scilit: