Ultra-thin TLDs for skin dose determination in high energy photon beams
- 6 July 2006
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 51 (14), 3549-3567
- https://doi.org/10.1088/0031-9155/51/14/018
Abstract
Estimation of surface dose is very important for patients undergoing radiation therapy. In this work we investigate the dose at the surface of a water phantom and at a depth of 0.007 cm, the practical reference depth for skin as recommended by ICRP and ICRU, with ultra-thin TLDs and Monte Carlo calculations. The calculations and measurements were carried out for fields ranging from 5 x 5 cm2 to 20 x 20 cm2 for 6 MV, 10 MV and 18 MV photon beams. The variation of the surface dose with angle of incidence and field size was investigated. Also, the exit dose was computed and measured for the same fields and angles of incidence. The dose at the ICRU reference depth was computed. Good agreement (+/-5%) was achieved between measurements and calculations. The surface dose at the entrance increased with the angle of incidence and/or the field size. The exit dose decreased with the angle of incidence but it increased with field size. The dose at the surface of the patient is mostly dependent on the beam energy, modality and beam obliquity rather than the field size and field separation. By correlating TLD measurements with Monte Carlo calculations, we were able to predict the dose at the skin surface with good accuracy. Knowing the dose received at the surface of the patient can lead to prediction of skin reactions helping with the design of new treatment techniques and alternative dose fractionation schemes.Keywords
This publication has 21 references indexed in Scilit:
- Validation of Monte Carlo calculated surface doses for megavoltage photon beamsMedical Physics, 2005
- Impact of Radiation Therapy on Acute Toxicity in Breast Conservation Therapy for Early Breast CancerClinical Oncology, 2004
- Surface and build‐up region dosimetry for obliquely incident intensity modulated radiotherapy 6 MV x raysMedical Physics, 2003
- Randomized phase III study comparing best supportive care to biafine as a prophylactic agent for radiation-induced skin toxicity for women undergoing breast irradiation: Radiation therapy oncology group (RTOG) 97-13International Journal of Radiation Oncology*Biology*Physics, 2000
- Dosimetric analysis of intact breast irradiation in off-axis planesInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Patterns of dose variability in radiation prescription of breast cancerRadiotherapy and Oncology, 1997
- Estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapyInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Presta: The parameter reduced electron-step transport algorithm for electron monte carlo transportNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1986
- The problem of obliquely incident beams in electron‐beam treatment planningMedical Physics, 1982
- X‐ray beam characteristics of the Varian Clinac 6‐100 linear acceleratorMedical Physics, 1980